  • Acid & Alkali Resistance: Constructed with PP material, offering corrosion, heat, and fire resistance for safe chemical handling.
  • Ductless Design: Self-contained unit that removes toxic vapors without requiring complex ductwork, saving installation costs.
  • Precise Velocity Control: Features manual control via electric air valve to maintain average surface air speed of 0.6-0.8 m/s.
  • Customizable Options: Product name and dimensions can be customized to fit specific laboratory requirements.
  • Multi-Field Application: Suitable for hospitals, schools, labs, and industries like pharmaceuticals, electronics, and forensics.
  • High Safety Standards: Includes explosion-proof features, LED lighting, and strict safety inspections for stable operation.
  • Efficient Purification: Uses spray sodium hydroxide solution to purify air, ensuring clean air recirculation into the environment.
  • Low Noise Operation: Operates within 55 decibels, providing a quiet working environment for laboratory staff.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Chemical Laboratory Fume Hood with Acid and Alkali Resistance

Chemical Laboratory Fume Hood with Acid and Alkali Resistance
Chemical Laboratory Fume Hood with Acid and Alkali Resistance pictures & photos
Chemical Laboratory Fume Hood with Acid and Alkali Resistance
Chemical Laboratory Fume Hood with Acid and Alkali Resistance pictures & photos
Chemical Laboratory Fume Hood with Acid and Alkali Resistance
Chemical Laboratory Fume Hood with Acid and Alkali Resistance pictures & photos
Chemical Laboratory Fume Hood with Acid and Alkali Resistance
Chemical Laboratory Fume Hood with Acid and Alkali Resistance pictures & photos
Chemical Laboratory Fume Hood with Acid and Alkali Resistance
Chemical Laboratory Fume Hood with Acid and Alkali Resistance pictures & photos
Chemical Laboratory Fume Hood with Acid and Alkali Resistance
Chemical Laboratory Fume Hood with Acid and Alkali Resistance pictures & photos
Chemical Laboratory Fume Hood with Acid and Alkali Resistance
  • Chemical Laboratory Fume Hood with Acid and Alkali Resistance
  • Chemical Laboratory Fume Hood with Acid and Alkali Resistance
    Chemical Laboratory Fume Hood with Acid and Alkali Resistance
  • Chemical Laboratory Fume Hood with Acid and Alkali Resistance
    Chemical Laboratory Fume Hood with Acid and Alkali Resistance
  • Chemical Laboratory Fume Hood with Acid and Alkali Resistance
    Chemical Laboratory Fume Hood with Acid and Alkali Resistance
  • Chemical Laboratory Fume Hood with Acid and Alkali Resistance
    Chemical Laboratory Fume Hood with Acid and Alkali Resistance
  • Chemical Laboratory Fume Hood with Acid and Alkali Resistance
    Chemical Laboratory Fume Hood with Acid and Alkali Resistance
  • Chemical Laboratory Fume Hood with Acid and Alkali Resistance
    Chemical Laboratory Fume Hood with Acid and Alkali Resistance

Find Similar Products

Product Description

Product Description


Choosing the right fume hood for your laboratory can be a challenge, and ductless fume hoods could be the solution you have been looking for. Whether you are working in an educational laboratory or an industrial location, having the right fume hood at your disposal is crucial. This piece of equipment is so important for the safety of your lab and your team, so choosing the right one is vital.

Also known as a recirculating fume enclosure or a filtered fume hood, a ductless unit is self-contained and works to remove toxic molecules, particles and vapour from the air. Having a chemical fume cabinet is likely to be the most essential piece of safety equipment your workplace can have. They clean the contaminated air to deliver clean air back into the environment. Compared with other types of chemical fume hoods, the ductless solutions can be more cost-efficient, easier to install and don't require ductwork around the building. Despite all these benefits, ductless fume hoods are not suitable for every situation. There are a few factors that you need to take into account before deciding if a this type of fume cupboard is suitable for your laboratory.

Product Parameters

 

                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Common Applications


Ductless fume hoods are used in various fields. Some of the most common applications are the following:

  • Life Sciences
  • Forensics, Fingerprinting and DNA
  • Educational Purposes
  • Clinics and Hospitals
  • Dental Laboratory
  • Cleanrooms
  • 3D Printing
  • Archaeology
  • Glass Manufacturing
  • Mycology
  • Soldering
  • Pharmaceutical
  • Art Restoration
  • Production of Glues, Paints, and Solvents
Detailed Photos
     
Chemical Laboratory Fume Hood with Acid and Alkali Resistance
Chemical Laboratory Fume Hood with Acid and Alkali Resistance
 
Chemical Laboratory Fume Hood with Acid and Alkali Resistance
Chemical Laboratory Fume Hood with Acid and Alkali Resistance

Application Cases

The ductless fume hood should be located away from disturbing influences which could cause drafts or affect air movement, such as open doors and windows, and should not be located near areas of heavy pedestrian traffic.

The owner shall ensure that records regarding the dates of installation and filter changes, maintenance and repairs, operator training, and chemical usage are maintained. These records shall be made available to Occupational Safety upon request.

Filters shall be those recommended or supplied by the manufacturer of the ductless fume hood only.

The owner shall ensure an evaluation of the filters after a spill to determine if a change is required. Often the high concentration of the spilled material is enough to saturate the filter, causing the contaminant to be readily discharged from the hood, potentially exposing the lab employee(s)

Chemical Laboratory Fume Hood with Acid and Alkali Resistance
Chemical Laboratory Fume Hood with Acid and Alkali Resistance

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR238059". Items marked "verified" are certified.

Watch Video
Watch Video
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.

About Our Factory & Business Background

Address
No. 11, 11th Floor, Unit 2, Building 2, No. 1, Section 1, Huayang Huafu Avenue, Tianfu New District, Chengdu, Sichuan, China
Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main Products
Chemical Fume Hood, Laboratory Fume Hood, Duct Fume Hood, Laboratory Furniture, Laboratory Storage Cabinet, Laboratory Equipment, Hospital Bed, Medical Device, Oxygen Concentrator, Veterinary Medical Equipment

Our Industry Experience & Global Business Record

Export Year
2019-07-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

Is this fume hood customizable?
Yes, the product name and dimensions can be customized to meet specific laboratory needs.
What materials is the fume hood made of?
The main material is Polypropylene (PP), with butterfly ceramics and ceramic fiber board for internal lining.
What is the average surface air speed?
The average surface air speed is controlled between 0.6-0.8 m/s using an electric air valve.
What are the common applications for this equipment?
It is widely used in hospitals, schools, laboratories, forensics, pharmaceuticals, and electronics industries.
How is the air purified in this ductless hood?
It uses a spray sodium hydroxide solution to purify the air, ensuring toxic molecules and vapors are removed.
What is the noise level of the fume hood?
The noise level is kept within 55 decibels to ensure a quiet working environment.
What are the payment terms accepted?
We accept LC, T/T, PayPal, Western Union, Small-amount payment, and Money Gram.
What is the lead time for production?
Peak season lead time is one month, while off-season lead time is within 15 workdays.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now