Chemical Laboratory High Performance Chemistry Fume Hood for Hospital

Product Details
Customization: Available
Material: Stainless Steel
Type: Bypass Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Chemical Laboratory High Performance Chemistry Fume Hood for Hospital
  • Chemical Laboratory High Performance Chemistry Fume Hood for Hospital
  • Chemical Laboratory High Performance Chemistry Fume Hood for Hospital
  • Chemical Laboratory High Performance Chemistry Fume Hood for Hospital
  • Chemical Laboratory High Performance Chemistry Fume Hood for Hospital
  • Chemical Laboratory High Performance Chemistry Fume Hood for Hospital
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Our Advantages
  • Detailed Photos
  • Application Cases
Overview

Basic Info.

Model NO.
WJ-1500B
Function
Exhaust, Velocity Control
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
Grey
Customized
Customized
Condition
New
Product Name
Lab Ventilation Hood
Worktop Material
20+6mm Ceramic
Liner Material
5 mm Ceramic Fiber
Worktop
1260(W)*780(D)*1100(H) mm
Input Power
380V/50A
Face Velocity
Manual Control 0.4-0.6m/S
Application
Office Building, Hospital, School, Laboratory
Faucet
UPVC
Transport Package
Standard Export Wooden Case Packing
Specification
1500(W)*1205(D)*2400(H) MM
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Packaging & Delivery

Package Size
1900.00cm * 900.00cm * 2100.00cm
Package Gross Weight
360.000kg

Product Description

Product Description

A device enclosed except for necessary exhaust purposes on three sides and top and bottom, designed to draw air inward by means of mechanical ventilation, operated with insertion of only the hands and arms of the user, and used to control exposure to hazardous substances. These devices are also known as laboratory fume hoods.

Chemical fume hoods, when used properly, are one of the most reliable engineering controls in the laboratory. They protect workers by:

  • Containing vapors, dusts, gases, and fumes generated within the hood, and removing them as air flows into the hood and then out via the laboratory exhaust system
  • Contributing to laboratory ventilation as air flows through the hood
  • Shielding the worker with a clear sliding window, called a sash, that contains aerosols and prevents injury from splashes, fires, or minor explosions that may occur inside the hood
Product Parameters
                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Our Advantages
  • Engineered to exhaust 50% less conditioned air from the laboratory
  • Designed to capture fumes while working in today's modern laboratories with varying factors such as lab traffic, fluctuating temperatures and interior hood loading
  • Fume capture and containment can be demonstrated with tracer gas testing
  • Low airflow provides an ideal environment for working with powders and delicate work
Detailed Photos


Chemical Laboratory High Performance Chemistry Fume Hood for Hospital
Chemical Laboratory High Performance Chemistry Fume Hood for Hospital
Chemical Laboratory High Performance Chemistry Fume Hood for Hospital
Chemical Laboratory High Performance Chemistry Fume Hood for Hospital

Application Cases

A fume hood is a ventilated enclosure used to control exposure to hazardous or odorous chemicals. An exhaust fan draws air into the front opening of the hood, then up and out of the hood through the ductwork. Because the air that is pulled into the hood is not filtered, fume hoods only offer protection to its users and no protection to the products inside the hood.

Hood performance and efficiency depends on an adequate and uniform velocity of air moving through the sash opening. Hood performance is adversely affected by many factors including mechanical malfunction, drafts or open doors and windows, and poor operating procedures of the person using the hood.

Chemical Laboratory High Performance Chemistry Fume Hood for Hospital
Chemical Laboratory High Performance Chemistry Fume Hood for Hospital

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier