Chemical Explosion Proof Laboratory Heat Resistant Fume Hood with Acid & Alkali Resistant

US$8,500.00
1-9 Sets
US$6,500.00
10-49 Sets
US$4,500.00
50+ Sets
Port:
Guangzhou, China
Production Capacity:
200 Set/Month
Payment Terms:
L/C, T/T, D/P, Western Union, Paypal, Money Gram

Last Login Date:

Jul 09, 2025

Business Type:

Manufacturer/Factory

Main Products:

Chemical Fume Hood, Laboratory Fume Hood, Duct Fume Hood, Laboratory Furniture, Laboratory Storage Cabinet, Laboratory Equipment, Hospital Bed, Medical Device, Oxygen Concentrator, Veterinary Medical Equipment

Find Similar Products

Product Description

Company Info

Basic Info.

Model NO.
WJ-1800B
Material
Stainless Steel
Type
Slit Type
Function
Exhaust, Velocity Control
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
Grey
Customized
Customized
Condition
New
Product Name
Fume Cupboard
Worktop
20+6 mm Ceramic
Liner Material
Ceramic Fiber Board
Input Power
380V/50A
Face Velocity
0.4-0.6 M/S
Application
Environment/Institute/Biology Lab/Chemical Lab
Trademark
Ample
Transport Package
Standard Export Wooden Case Packing
Specification
1800*1205*2400 MM
Origin
Chengdu, China
HS Code
8414809090

Product Description

Product Description

A fume hood essentially looks like an enclosed industrial workbench. To break it down, a fume hood is made up of:

The body: The body of the fume hood contains a work surface, enclosed completely on three sides, on which lab personnel can conduct their experiments / research.

The sash: The sash is the fourth side to the hood, basically a window between the employee and the volatile compounds he or she is working with.

The exhaust duct: The exhaust duct releases any contaminated air to the outside. Usually this duct is connected to the building's HVAC infrastructure, but there are ductless fume hoods available if flexibility, lower cost, and energy efficiency are key drivers for your business or institution.

The baffles: The baffles are slotted panels that control the amount of air flowing into the hood from the surrounding environment

Product Parameters
 
                Model Specification  WJ-1500AWJ-1500BWJ-1800AWJ-1800B
External dimensions of equipment(mm)1500(W)*1205 (D) *2400 (H)1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm)1260(W1)*780(D1) *1100 (H1)1560(W1)*780(D1) *1100 (H1)
Panel material20+6mm thick butterfly ceramics
Material of internal lining board5mm thick ceramic fiber board
Diversion structureLower air return
Control systemButton control panel (LCD panel)
PH value controlThe medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input powerThree-phase five-wire 380V/50A
Current for air fanNot over 2.8A(380V or 220V can be directly connected)
Maximum load of socket12 KW(total of 4 sockets)
Water tap1 set (remote control valve + water nozzle)No1 set (remote control valve + water nozzle)No
Water discharge wayMagnetic chemical pump strong discharge
Using environmentFor non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fieldsInorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of PurificationSpray sodium hydroxide solution, no less than 8 cubic meters/hourSpray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed controlManual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm)0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface airNot higher than 10%
The average intensity of illuminationNot less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
NoiseWithin 55 decibels
Flow displayWhite smoke can pass through the exhaust outlet, no overflow.
Safety inspectionNo spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinetLess than 160 pa
Power consumptionLess than 1.0kw/h (excluding power consumption of fans and external instruments)Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumptionLess than 3.2L/ hLess than 4.0L/ h
Performance of wind compensationWith a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
More About the Fume Hood

Before usage
1. Before using the fume hood, make sure you have been trained in proper use of the equipment. If you don't know how to use it, ask someone to demonstrate.
2. Understand the potential reactions of the chemicals you are working with (could this chemical explode, liquefy or evaporate under certain circumstances).
3. Open the sash to the proper operating height. Note: If the sash is too high, there is not enough of a barrier between you and the chemicals to provide protection.
4. Check that the air gauge shows that air flow is within the required range.

During usage
1.Don't ever let your head enter the fume hood beyond the sash (this is not going to protect you if something happens within the fume hood). 
2.
Use eye protection.

3. Try to limit motion around and in front of the hood while you're working. Excess movement could cause the fume hood to vibrate and disrupt airflow.
4. Don't block baffles or exhaust slots while working in the fume hood, this would prevent air from flowing into and out of the hood.
5. Keep all materials at least six inches from the sash opening inside of the hood.
6. When not working in the hood, close the sash and never store any chemicals inside the hood while it's not in use.
7. Know your laboratory's action plan in case of an emergency while handling toxic chemicals.
Detailed Photos
           
 


     
Fume Hood Maintenance

Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.

• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.

 Fume  hoods should  be certified, at  least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies  have shown that face velocity is not a good predictor of fume hood leakage.

• Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.

 Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from  exposure to vapors,  aerosols, toxic  materials,  odorous,  and  other  harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.
FAQ

6 Questions to Ask When Buying a Fume Hood:

-Which chemicals will you use within the hood?

-Is a ducted or ductless hood best suited to your needs and available space?

-Where will you place the fume hood in the lab? Consider workflows, access to external exhaust systems, and competing air patterns.

-What size fume hood will best suit your needs? Be sure to consider what (if any) equipment will be enclosed in the hood.

-Are any service fixtures or accessories such as airflow monitors, electrical outlets, water, or gas fixtures required?

-Are base cabinets for acid, solvent, or non-chemical storage required?