Secured Trading Service

Acid & Alkali Resistant Chemical Fume Hood for School Experiment

Chengdu Ample Import and Export Co., Ltd.
  • Audited Supplier
  • 5 yrs

Contact Supplier

Product Highlights

  • Corrosion & Acid Resistance: Constructed with stainless steel and ceramic materials for superior acid and alkali resistance.
  • Customizable Dimensions: Available in multiple sizes including 1500mm and 1800mm widths to fit specific lab needs.
  • Advanced Control System: Features LCD panel, PH value monitoring, and manual control via acid/alkali pumps.
  • High Efficiency Ventilation: Exhaust volume ranges from 1420 to 2340 m3/h with adjustable face velocity.
  • Safety & Explosion Proof: Designed with fireproof and explosion-proof features for safe handling of hazardous materials.
  • Ceramic Worktop & Lining: Worktop is 20+6mm thick butterfly ceramics with 5mm ceramic fiber board internal lining.
  • Low Noise Operation: Operates at noise levels within 55 decibels for a quiet laboratory environment.
  • Adjustable Illumination: Equipped with standard white and UV-free yellow LED lamps with adjustable intensity.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Acid & Alkali Resistant Chemical Fume Hood for School Experiment

Acid & Alkali Resistant Chemical Fume Hood for School Experiment
Acid & Alkali Resistant Chemical Fume Hood for School Experiment pictures & photos
Acid & Alkali Resistant Chemical Fume Hood for School Experiment
Acid & Alkali Resistant Chemical Fume Hood for School Experiment pictures & photos
Acid & Alkali Resistant Chemical Fume Hood for School Experiment
Acid & Alkali Resistant Chemical Fume Hood for School Experiment pictures & photos
Acid & Alkali Resistant Chemical Fume Hood for School Experiment
Acid & Alkali Resistant Chemical Fume Hood for School Experiment pictures & photos
Acid & Alkali Resistant Chemical Fume Hood for School Experiment
Acid & Alkali Resistant Chemical Fume Hood for School Experiment pictures & photos
Acid & Alkali Resistant Chemical Fume Hood for School Experiment
Acid & Alkali Resistant Chemical Fume Hood for School Experiment pictures & photos
Acid & Alkali Resistant Chemical Fume Hood for School Experiment
  • Acid & Alkali Resistant Chemical Fume Hood for School Experiment
  • Acid & Alkali Resistant Chemical Fume Hood for School Experiment
    Acid & Alkali Resistant Chemical Fume Hood for School Experiment
  • Acid & Alkali Resistant Chemical Fume Hood for School Experiment
    Acid & Alkali Resistant Chemical Fume Hood for School Experiment
  • Acid & Alkali Resistant Chemical Fume Hood for School Experiment
    Acid & Alkali Resistant Chemical Fume Hood for School Experiment
  • Acid & Alkali Resistant Chemical Fume Hood for School Experiment
    Acid & Alkali Resistant Chemical Fume Hood for School Experiment
  • Acid & Alkali Resistant Chemical Fume Hood for School Experiment
    Acid & Alkali Resistant Chemical Fume Hood for School Experiment
  • Acid & Alkali Resistant Chemical Fume Hood for School Experiment
    Acid & Alkali Resistant Chemical Fume Hood for School Experiment

Find Similar Products

Product Description

 
Product Description

A laboratory fume hood is a ventilated enclosure where hazardous materials can be    handled safely. The purpose of the hood is to contain contaminants and prevent their  escape into the laboratory. This is accomplished by drawing (by air flow) contaminants within the hood's work area away from the user thereby preventing and minimizing inhalation and contact with hazardous materials.

To create airflow into the hood, an exhaust blower "pulls" air from the laboratory room into and through the hood and exhaust system . A baffle, airfoil, and other aerodynamically designed components control the patterns of air moving into and through the hood.

Fume Hoods must be located away from heavy traffic aisles and doorways so that persons  exiting the lab do not have to pass in front of the fume hood. The potentially dangerous portion of an experiment is usually conducted in a fume hood. Many lab fires and explosions originate in fume hood and a fume hood located adjacent to a path of egress could trap someone in the lab.

There must be two exits from rooms where new fume hoods are to be installed. If this is not feasible, the fume hood must be situated on the side of the room furthest from the   door. A fire or chemical hazard, both of which often start in a fume hood, can render an exit impassible. For this reason, all labs with fume hoods are required to maintain two unblocked routes of egress.

Product Parameters
 
                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Installation Instructions

•Fume hoods should be located within the laboratory to avoid cross currents at the fume hood face due to heating cooling, or ventilation supply or exhaust diffusers.Cross currents outside a hood can nullify or divert air flow onto a hood, negatively affecting its capture ability.

•Sufficient makeup air must be available within the laboratory to permit fume hoods to operate at their specified face velocities. A fume hood exhausts a substantial amount of air. Therefore, additional makeup air must be brought onto the room to maintain a proper air balance.

• Windows in labs that have fume hoods must be fixed closed. Breezes coming in through open lab windows can adversely affect the proper functioning of the hood. Turbulence caused by these wind currents can easily bring the contaminated air inside the hood back into the laboratory.

•Safety devices such as deluge showers, eye wash stations, fire extinguishers, and fire blankets should be located convenient to the fume hood operating personnel.

•Fume hoods shall not have an on/off control accessible in the laboratory, unless the lab has an alternate exhaust ventilation system or the exhaust is being filtered through a charcoal or HEPA filter. Fume hoods are an integral part of the entire laboratory's air balancing system which must be maintained. Labs must be maintained under positive pressure and when a fume hood is turned off the lab can develop positive pressure.

Detailed Photos
  
Acid & Alkali Resistant Chemical Fume Hood for School Experiment
Acid & Alkali Resistant Chemical Fume Hood for School Experiment
 
Acid & Alkali Resistant Chemical Fume Hood for School Experiment
Acid & Alkali Resistant Chemical Fume Hood for School Experiment

Usage Attention

• Do not use the hood as a waste disposal mechanism. Apparatus used in a hood should be fitted with condensers, traps, or scrubbers to contain and collect waste solvents, toxic vapors or dust. Proper disposal of waste and code compliance should be practiced.

• Limit chemical storage in fume hoods. Keep the smallest amount of chemicals in the hood needed to conduct the procedure at hand.

• Do not use the hood as a storage area. Items can block airflow and interfere with containment. Store hazardous chemicals such as flammable liquids in an approved safety cabinet.

• Do not leave uncapped bottles of reagents in a hood. Although a hood is used to exhaust fumes out of the laboratory, minimizing the amount of evaporation and fuming is desirable for the environment and operator safety.

• Always use good housekeeping techniques to maintain the hood at optimal performance levels. Excessive storage of materials or equipment can cause eddy currents or reverse flow resulting in contaminants escaping from the hood.

Fume Hood Maintenance

• Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.

• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.

• Fume  hoods should  be certified, at  least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies  have shown that face velocity is not a good predictor of fume hood leakage.

• Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.

• Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from  exposure to vapors,  aerosols, toxic  materials,  odorous,  and  other  harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR238059". Items marked "verified" are certified.

Watch Video
Watch Video
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.

About Our Factory & Business Background

Address
No. 11, 11th Floor, Unit 2, Building 2, No. 1, Section 1, Huayang Huafu Avenue, Tianfu New District, Chengdu, Sichuan, China
Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main Products
Chemical Fume Hood, Laboratory Fume Hood, Duct Fume Hood, Laboratory Furniture, Laboratory Storage Cabinet, Laboratory Equipment, Hospital Bed, Medical Device, Oxygen Concentrator, Veterinary Medical Equipment

Our Industry Experience & Global Business Record

Export Year
2019-07-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What materials are used for the fume hood?
The hood is made of stainless steel with a 20+6mm thick butterfly ceramic worktop and 5mm ceramic fiber board internal lining.
What are the available dimensions?
We offer models with external dimensions of 1500(W)*1205(D)*2400(H) and 1800(W)*1205(D)*2400(H).
How is the air velocity controlled?
Velocity is controlled manually via an electric air valve or by adjusting the height of the moving door, with an average speed of 0.6-0.8 m/s.
Is the product customizable?
Yes, the product name, worktop, liner material, and other specifications can be customized according to requirements.
What is the power consumption?
Power consumption is less than 1.0kw/h for the 1500A model and less than 1.2kw/h for the 1800A model, excluding fans.
What is the lead time for orders?
During peak season, the lead time is one month. In the off-season, it is within 15 workdays.
What safety features does the hood have?
It includes fireproof, explosion-proof features, and requires two unblocked routes of egress for the installation room.
What is the warranty or maintenance requirement?
Hoods should be certified annually to ensure safe operation, including face velocity measurements and smoke tests.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.