Secured Trading Service

Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry

Chengdu Ample Import and Export Co., Ltd.
  • Audited Supplier
  • 5 yrs

Contact Supplier

Product Highlights

  • Acid & Alkali Resistance: Constructed with stainless steel and ceramic materials for superior corrosion and heat resistance.
  • Customizable Design: Fully customized options for product name, worktop, liner material, and input power specifications.
  • Precise Velocity Control: Features manual control via LCD panel and electric air valve for stable face velocity of 0.6-0.8 m/s.
  • Advanced Purification: Equipped with spray sodium hydroxide solution system for effective neutralization of acidic fumes.
  • Safety & Monitoring: Includes PH value monitoring, adjustable LED illumination, and low noise operation under 55 decibels.
  • Versatile Application: Suitable for inorganic chemistry, food, medicine, electronics, environment, and metallurgy labs.
  • Energy Efficient: Low power consumption under 1.2kw/h and water consumption under 4.0L/h for cost-effective operation.
  • Robust Construction: Features 20+6mm thick butterfly ceramics worktop and 5mm ceramic fiber board for durability.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry

Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry pictures & photos
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry pictures & photos
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry pictures & photos
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry pictures & photos
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry pictures & photos
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry pictures & photos
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
  • Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
  • Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
    Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
  • Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
    Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
  • Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
    Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
  • Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
    Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
  • Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
    Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
  • Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
    Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry

Find Similar Products

Product Description

 
Product Description


A ventilated enclosure where harmful or toxic fumes or vapors can be safely handled while protecting the laboratory technician. The primary function of a fume hood is to capture, contain and remove airborne contaminants.

Airflow into a hood is achieved by an exhaust blower which "pulls" air from the laboratory room into and through the hood and exhaust system. This "pull" at the opening of the hood is measured as face velocity.
Air volume passing through a fume hood is generally equal to the area of the sash opening multiplied by the average velocity desired. For example, if 100 feet per minute (fpm) is required and the hood has a sash opening of 7.5 square feet, then the hood's air volume is 750 (7.5 x 100) cubic feet perminute (CFM).

Product Parameters
 
                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
More About the Fume Hood

Fume cupboards should have good airflow which should be checked regularly. Many models are fitted with alarm systems which warn of low air flow caused by fan failure or clogged filters. All fume cupboards must undergo a full inspection at least every 14 months and it is advisable to carry out a filter saturation test at the same time. Some advisory bodies provide filter testing training. Independent test houses and fume cupboard manufacturers can provide this service.

There is no such thing as a one size fits all universal filter, so it is important to ensure the filter chosen is suitable for the intended application. Guidance is available from the manufacturers and the growing popularity of recirculating fume cupboards in schools due to cost and flexibility advantages has resulted in the creation of application lists and the development of filters suited to the typical range of activities carried out in school laboratories.

Fume hoods and accessories represent one of the largest expenditures that a laboratory manager faces. The cost of air filtration does not end at the initial purchase price of a fume hood. Construction of ductwork and placement of utilities may be a one-time expense, however the ongoing cost of power and the increased HVAC load on the facility can be significant.

Traditional "ducted" fume hoods are connected to existing facility ductwork and pull contaminated air through the hood and direct it outside the facility and into the atmosphere. Ducted fume hoods can be filtered or unfiltered depending on the design and application. Ductless fume hoods contain filters which clean contaminated air and recirculate it directly back into the laboratory. No additional ductwork is required to exhaust air to the outside. Ductless fume hoods provide the same filtration capabilities as ducted hoods, but are easier to install, have lower initial installation costs and can be highly efficient.
Detailed Photos
          
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry

  
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry
Acid & Alkali Resistant Lab Chemical Fume Hood for Chemistry


  
Fume Hood Maintenance
 

• Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.

• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.

• Fume  hoods should  be certified, at  least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies  have shown that face velocity is not a good predictor of fume hood leakage.

• Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.

• Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from  exposure to vapors,  aerosols, toxic  materials,  odorous,  and  other  harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.
FAQ

6 Questions to Ask When Buying a Fume Hood:

-Which chemicals will you use within the hood?

-Is a ducted or ductless hood best suited to your needs and available space?

-Where will you place the fume hood in the lab? Consider workflows, access to external exhaust systems, and competing air patterns.

-What size fume hood will best suit your needs? Be sure to consider what (if any) equipment will be enclosed in the hood.

-Are any service fixtures or accessories such as airflow monitors, electrical outlets, water, or gas fixtures required?

-Are base cabinets for acid, solvent, or non-chemical storage required?

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR238059". Items marked "verified" are certified.

Watch Video
Watch Video
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.

About Our Factory & Business Background

Address
No. 11, 11th Floor, Unit 2, Building 2, No. 1, Section 1, Huayang Huafu Avenue, Tianfu New District, Chengdu, Sichuan, China
Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main Products
Chemical Fume Hood, Laboratory Fume Hood, Duct Fume Hood, Laboratory Furniture, Laboratory Storage Cabinet, Laboratory Equipment, Hospital Bed, Medical Device, Oxygen Concentrator, Veterinary Medical Equipment

Our Industry Experience & Global Business Record

Export Year
2019-07-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What materials are used for the fume hood construction?
The fume hood is made of stainless steel with a 20+6mm thick butterfly ceramics worktop and a 5mm thick ceramic fiber board internal lining.
Can the fume hood be customized?
Yes, the product is fully customized, including options for the product name, worktop, liner material, input power, and face velocity.
How is the face velocity controlled?
Face velocity is controlled manually through an electric air valve to adjust exhaust air volume or by adjusting the height of the moving door, maintaining 0.6-0.8 m/s.
What is the purification method for this fume hood?
It uses a spray sodium hydroxide solution system with a flow rate of no less than 8-12 cubic meters/hour to neutralize acidic fumes.
What are the power and water consumption specifications?
Power consumption is less than 1.0-1.2kw/h (excluding fans), and water consumption is less than 3.2-4.0L/h depending on the model.
What safety features does the fume hood include?
It includes PH value monitoring, adjustable LED illumination (not less than 700 Lux), noise control under 55 decibels, and a wind compensation structure.
What are the typical applications for this fume hood?
It is suitable for inorganic chemistry experiments, as well as food, medicine, electronics, environment, metallurgy, and mining laboratories.
What are the terms of payment and lead time?
Payment terms include LC, T/T, PayPal, Western Union, and others. Lead time is within 15 workdays off-season and one month during peak season.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now