  • Corrosion Resistance: Constructed with stainless steel and ceramic materials for acid, alkali, and chemical resistance.
  • Customizable Design: Product name, worktop, liner material, and power input can be customized to specific needs.
  • Safety Certification: Features explosion-proof, fireproof, and safety inspection capabilities for hazardous environments.
  • Advanced Control System: Includes LCD panel, pH value control, and manual monitoring via acid/alkali pumps.
  • High Efficiency Exhaust: Delivers average surface air speed of 0.6-0.8 m/s with adjustable exhaust volume.
  • Low Noise Operation: Operates within 55 decibels to ensure a quiet laboratory environment.
  • Energy Efficient: Power consumption is less than 1.2kw/h, excluding fans and external instruments.
  • Wind Compensation Structure: Unique design prevents turbulence and direct airflow to staff members.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Corrosion Resistance High Performance Fume Hood for Laboratory

Corrosion Resistance High Performance Fume Hood for Laboratory
Corrosion Resistance High Performance Fume Hood for Laboratory pictures & photos
Corrosion Resistance High Performance Fume Hood for Laboratory
Corrosion Resistance High Performance Fume Hood for Laboratory pictures & photos
Corrosion Resistance High Performance Fume Hood for Laboratory
Corrosion Resistance High Performance Fume Hood for Laboratory pictures & photos
Corrosion Resistance High Performance Fume Hood for Laboratory
Corrosion Resistance High Performance Fume Hood for Laboratory pictures & photos
Corrosion Resistance High Performance Fume Hood for Laboratory
Corrosion Resistance High Performance Fume Hood for Laboratory pictures & photos
Corrosion Resistance High Performance Fume Hood for Laboratory
Corrosion Resistance High Performance Fume Hood for Laboratory pictures & photos
Corrosion Resistance High Performance Fume Hood for Laboratory
  • Corrosion Resistance High Performance Fume Hood for Laboratory
  • Corrosion Resistance High Performance Fume Hood for Laboratory
    Corrosion Resistance High Performance Fume Hood for Laboratory
  • Corrosion Resistance High Performance Fume Hood for Laboratory
    Corrosion Resistance High Performance Fume Hood for Laboratory
  • Corrosion Resistance High Performance Fume Hood for Laboratory
    Corrosion Resistance High Performance Fume Hood for Laboratory
  • Corrosion Resistance High Performance Fume Hood for Laboratory
    Corrosion Resistance High Performance Fume Hood for Laboratory
  • Corrosion Resistance High Performance Fume Hood for Laboratory
    Corrosion Resistance High Performance Fume Hood for Laboratory
  • Corrosion Resistance High Performance Fume Hood for Laboratory
    Corrosion Resistance High Performance Fume Hood for Laboratory

Find Similar Products

Product Description

 
Product Description

Before you buy a fume hood, it's important to know what fume hoods are and what they are not. Fume hoods are a primary means of safety from hazardous fumes and vapors.

A fume hood is just one part of a whole system that includes a base cabinet (for benchtop hoods), a work surface, ductwork, and exhaust blower. When purchasing a fume hood, the first thing you need to know is what size fume hood you need. The questions to ask yourself include: How much space do I have? Am I putting the fume hood on an existing countertop? If so, how deep is it? It's important to know that all work done inside a fume hood needs to be at least six inches behind the sash and that there needs to be some clearance underneath any equipment in the fume hood.

Compatibility also comes into play when looking at a fume hood purchase. This includes knowing the types of chemicals you'll be working with. Find out if you need personnel protection only or product protection also. If you are working with perchloric acid, you will need an exhaust wash-down feature. If you are working with delicate instruments or powders, you may need a constant volume air movement hood, versus a variable air volume hood

Product Parameters
 
                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Our Advantages

Laboratory safety and workload should be the primary deciding factors in your decision. In a ductless fume hood, there should be no extreme heating, no more than 10 chemicals should be used per application, small volumes of chemicals should be used (approximately 500 ml or less) and exposure time should be within 2-3 hours per day.

There are a range of filters that have different chemical trapping capacities, but if your application doesn't match available filters you'll be required to move forward with a ducted fume hood. Talk to your fume hood provider about the various filters for chemical groups.

Determine how often you will be replacing your carbon filter, this will also give you a more accurate financial cost. Keep in mind that the filter life depends on the chemicals used, evaporation rate, chemical volume, duration of usage and the temperature of the chemicals.

Advantages and Disadvantages of Ducted Fume Hoods

Advantages Disadvantages
Safer for lab workers More expensive
Can handle a wide range of chemicals More difficult to install
Easy to operate and maintain Stationary in the lab
Exhaust system keeps contamination outside lab More difficult to move or relocate
  Uses more energy

Advantages and Disadvantages of Ductless Fume Hoods
 
Advantages Disadvantages
Less expensive Handles Limited chemicals
Easy to install Need to replace filters 
Mobile in the lab Not as effective at removing chemical fumes
Easily moved or relocated Not for constant use
Use less energy  
Detailed Photos
            
Corrosion Resistance High Performance Fume Hood for Laboratory
Corrosion Resistance High Performance Fume Hood for Laboratory
Corrosion Resistance High Performance Fume Hood for Laboratory
Corrosion Resistance High Performance Fume Hood for Laboratory
 
Fume Hood Maintenance
 

• Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.

• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.

• Fume  hoods should  be certified, at  least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies  have shown that face velocity is not a good predictor of fume hood leakage.

• Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.

• Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from  exposure to vapors,  aerosols, toxic  materials,  odorous,  and  other  harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.
FAQ

6 Questions to Ask When Buying a Fume Hood:

-Which chemicals will you use within the hood?

-Is a ducted or ductless hood best suited to your needs and available space?

-Where will you place the fume hood in the lab? Consider workflows, access to external exhaust systems, and competing air patterns.

-What size fume hood will best suit your needs? Be sure to consider what (if any) equipment will be enclosed in the hood.

-Are any service fixtures or accessories such as airflow monitors, electrical outlets, water, or gas fixtures required?

-Are base cabinets for acid, solvent, or non-chemical storage required?

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR238059". Items marked "verified" are certified.

Watch Video
Watch Video
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.

About Our Factory & Business Background

Address
No. 11, 11th Floor, Unit 2, Building 2, No. 1, Section 1, Huayang Huafu Avenue, Tianfu New District, Chengdu, Sichuan, China
Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main Products
Chemical Fume Hood, Laboratory Fume Hood, Duct Fume Hood, Laboratory Furniture, Laboratory Storage Cabinet, Laboratory Equipment, Hospital Bed, Medical Device, Oxygen Concentrator, Veterinary Medical Equipment

Our Industry Experience & Global Business Record

Export Year
2019-07-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

Which chemicals will you use within the hood?
Determine the specific chemicals to be used to ensure compatibility with the hood's filtration or exhaust system.
Is a ducted or ductless hood best suited to your needs and available space?
Choose based on the volume of chemicals, required safety level, and available space for installation.
Where will you place the fume hood in the lab?
Consider workflows, access to external exhaust systems, and competing air patterns when selecting a location.
What size fume hood will best suit your needs?
Select a size that accommodates the equipment to be enclosed while maintaining proper clearance and safety margins.
Are any service fixtures or accessories required?
Check if airflow monitors, electrical outlets, water, or gas fixtures are needed for your specific application.
Are base cabinets for acid, solvent, or non-chemical storage required?
Determine if additional storage cabinets are necessary for safe storage of hazardous or non-hazardous materials.

Send your message to this supplier