Product Highlights

  • Customized Configuration: Product name, worktop, liner material, and dimensions are fully customizable to meet specific lab needs.
  • Superior Chemical Resistance: Constructed with ceramic fiber board and butterfly ceramics for corrosion, acid, alkali, and heat resistance.
  • Optimal Face Velocity Control: Maintains safe air velocity between 0.4-0.8 m/s to prevent turbulence and ensure contaminant containment.
  • Advanced Safety Features: Includes explosion-proof design, fireproof materials, and sash stops to protect users from hazardous exposure.
  • High Efficiency Purification: Utilizes spray sodium hydroxide solution with air volume up to 12 cubic meters/hour for effective gas purification.
  • Energy Efficient Operation: Low power consumption under 1.2kw/h and noise levels within 55 decibels for a quiet working environment.
  • Durable Stainless Steel Build: Features stainless steel construction with tempered safety glass sash for long-lasting durability and strength.
  • Versatile Laboratory Application: Suitable for inorganic chemistry, food, medicine, electronics, environment, metallurgy, and mining experiments.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b

High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b pictures & photos
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b pictures & photos
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b pictures & photos
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b pictures & photos
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b pictures & photos
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b pictures & photos
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
  • High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
  • High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
    High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
  • High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
    High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
  • High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
    High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
  • High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
    High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
  • High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
    High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
  • High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
    High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b

Find Similar Products

Product Description

 
Product Description


A chemical hood can be used for storage of volatile, flammable, or odiferous materials when an appropriate storage cabinet is not available. While it is appropriate to keep chemicals that are being used during a particular experiment inside the chemical hood, hoods are not designed for permanent chemical storage. Each item placed on the work surface interferes with the directional airflow, causing turbulence and eddy currents that allow contaminants to be drawn out of the hood. Even with highly volatile materials, as long as a container is properly capped evaporation will not add significantly to worker exposures. Unlike a chemical hood, flammable materials storage cabinets provide additional protection in the event of a fire.

When working with highly hazardous materials, the higher the face velocity the better.
 While it is important to have a face velocity between 0.3 m/s (60 fpm) and 0.5 m/s (100 fpm), velocities higher than this are actually harmful. When face velocity exceeds 0.6 m/s (125 fpm) eddy currents are created which allow contaminants to be drawn out of the hood, increasing worker exposures. Check with local safety regulations on the maximum face velocity before using the hood.


The airfoil on the front of a hood is of minor importance. It can safely be removed if it interferes with my experimental apparatus.
Airfoils are critical to efficient operation of a chemical hood. With the sash open an airfoil smoothes flow over the hood edges. Without an airfoil eddy currents form, causing contaminates to be drawn out of the hood. With the sash closed, the opening beneath the bottom airfoil provides for a source of exhaust air.

Product Parameters
 
                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Our Advantages

UniFlow Superstructure exclusive unitized dual wall construction for superior chemical resistance, strength, and durability. 1 piece interior fume chamber to be glass-smooth with VaraFlow baffle system & bell shaped exhaust collar.

Access Panel removable to access ducting connections and electrical services from a single point electrical box, 115V/60Hz AC operation.

Sash is perfectly counter balanced, 3/16 tempered safety glass, coated stainless steel cable with stainless steel pulley assembly. Framed in nonmetallic PVC framing, track, and aerodynamic sash lift for ease of movement and air flow efficiency.

Plumbing Services are color coded to specific service. 

Fume Hood Fire Extinguisher optional feature.

Epoxy Work Surfaces optional feature.

Fume Hood Base Cabinet optional feature.

Sash Stop located at 1/2 open position to reduce air flow 50%.

Air Flow Monitor continuously monitors face velocity air flow, comes standard with analog, digital available.

Detailed Photos
    
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
 
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b
High Performance Ceramic Fiber Board Laboratory Fume Hood Wj-1800b

Usage Attention

If you work on the inside of the ductwork or on the fans, follow this procedure :

-Notify the group that owns the hood five days before the work is to  begin. Tell them that they won't be able to use the hood during the  work. The lab must also take every container out of the hood for the duration of the shutdown.

 
-Notify the Environmental Safety Compliance Officer (ESCO) and the Facilities Manager of the shutdown. The ESCO must verify that it has been cleaned and is safe to perform work on it.
 
-Following the standard lockout procedure, lock off the fan and lock the sashes closed on all the fume hoods connected to the fan and ductwork.
 
-Steam clean, pressure wash or clean with warm soapy water and a brush any parts that might be contacted during the work. Collect all the wash water for disposal if hazardous.

The person doing the cleaning must wear chemical splash protection during the procedure, including:
• Lab coat or apron,
• Disposable latex or neoprene gloves, and
• Full or half face respirator and splash goggles. The respirators should have high efficiency particulate air filters (HEPA).
Fume Hood Maintenance

• Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.

• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.

• Fume  hoods should  be certified, at  least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies  have shown that face velocity is not a good predictor of fume hood leakage.

• Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.

• Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from  exposure to vapors,  aerosols, toxic  materials,  odorous,  and  other  harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR238059". Items marked "verified" are certified.

Watch Video
Watch Video
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.

About Our Factory & Business Background

Address
No. 11, 11th Floor, Unit 2, Building 2, No. 1, Section 1, Huayang Huafu Avenue, Tianfu New District, Chengdu, Sichuan, China
Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main Products
Chemical Fume Hood, Laboratory Fume Hood, Duct Fume Hood, Laboratory Furniture, Laboratory Storage Cabinet, Laboratory Equipment, Hospital Bed, Medical Device, Oxygen Concentrator, Veterinary Medical Equipment

Our Industry Experience & Global Business Record

Export Year
2019-07-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

Is the product customizable?
Yes, the product name, worktop, liner material, input power, and dimensions are fully customizable.
What materials are used for the construction?
The product features stainless steel, 20+6mm thick butterfly ceramics for the worktop, and 5mm thick ceramic fiber board for the internal lining.
What is the recommended face velocity?
The optimal face velocity is between 0.4-0.8 m/s. Velocities higher than 0.6 m/s can create eddy currents and increase worker exposure.
What are the safety features of this fume hood?
It includes explosion-proof and fireproof features, sash stops, and is designed to protect users from vapors, aerosols, and toxic materials.
How is the air purification achieved?
Purification is achieved by spraying sodium hydroxide solution with an air volume of at least 8 to 12 cubic meters per hour.
What is the power consumption and noise level?
Power consumption is less than 1.2kw/h (excluding fans), and the noise level is within 55 decibels.
What are the applicable fields for this equipment?
It is suitable for inorganic chemistry, food, medicine, electronics, environment, metallurgy, and mining applications.
What is the lead time for orders?
During peak season, the lead time is one month. During off-season, it is within 15 workdays.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now