Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof

Product Details
Customization: Available
Material: Stainless Steel
Type: Bypass Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof
  • Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof
  • Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof
  • Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof
  • Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof
  • Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof
Find Similar Products

Basic Info.

Model NO.
YZ-1500A-1 / YZ-1500B-1 / YZ-1500C-1
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
Blue
Customized
Customized
Condition
New
Product Name
Fume Hood
Cabinet
Multi-Layer Solid Wood
Sash
Tempered Glass
Airflow
Ceramic Fiber
Work Surface
Ceramic
Liner
Ceramic Fiber
Transport Package
Standard Export Wooden Case Packing
Specification
1500*1205*2400(mm)
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
100 Set/Month

Packaging & Delivery

Package Size
1900.00cm * 900.00cm * 2100.00cm
Package Gross Weight
500.000kg

Product Description

1. Product Description

Fume hoods are an integral part of most labs. These ventilated enclosures enable laboratory personnel to safely work with materials that produce hazardous fumes and volatile vapors. Selecting a fume hood that is the right fit for your laboratory is important and there are many different ducted and ductless designs to choose from. Traditionally, fume hoods consume large amounts of energy, but many newer units are designed with energy efficiency in mind, which reduces operating costs while providing the necessary protection.

    Product features:

    1. Easy to assemble; Anti-corrosion and high temperature resistance;
    2. Unique down return air, timely and effectively exhaust without residual;
    3. Special flow-equalized design makes the flow even without any blind angle;
    4. The internal visual range will not form condensate due to temperature difference, therefore no drip will form;
    5. The internal airflow direction is not affected by the volume of the exhaust air, thus will not cause turbulence;
    6. Low energy consumption, easy to operate;
    7. Has air compensation channel and connection, saves energy, comfortable;
    8. Drainage will not be limited by the height of the drain,since it has pump to lift the sewage;; 
     
    Product function:
    1. Exhaust waste gas;
    2. New air compensation;
    3. Inorganic exhaust gas purification;
    4. Sewage treatment function (Acid and alkali neutralization);
    5. All electrical and mechanical devices can start and stop independently;
    6. Purification system resistance monitoring: auto-alarm when the set value is exceeded;
    7. Purification system temperature monitoring: auto-alarm when the set value is exceeded, and automatically cut off
    the outlet power;
    8. Auto-monitoring the level of acid, alkali and spray media;
    9. Manual add acid and alkali  (via dosing pump);
    10. Manual discharge of sewage (via sewage pump) and cleaning of spray system (via spray pump);
    11. Auto-replenishment of tap-water (via feed-water valve);
    12. Provide safe power supply (including phase-out and phase-sequence protection, Emergency power cuts, Leakage protection,
    Main power control;
    13. Safe light source (including adjustable white and non-UV yellow LED lights), external isolate installation;
    14. Water shortage protection for sewage pump and spray pump; 15. Overheat protection for mechanical and
    electrical equipment;
    16. Alarm when sliding door in extra high position;
    17. The exhaust air volume is controlled by electric regulating valve;
    18. Other functions: water supply terminal, gas supply terminal and other experimental equipment can be installed according to
    customers' demands.

     
    2. Product Parameters
     
                  Model  
          Specification
    WJ-1500A WJ-1500B WJ-1800A WJ-1800B
    External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
    Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
    Panel material 20+6mm thick butterfly ceramics
    Material of internal lining board 5mm thick ceramic fiber board
    Diversion structure Lower air return
    Control system Button control panel (LCD panel)
    PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
    Input power Three-phase five-wire 380V/50A
    Current for air fan Not over 2.8A(380V or 220V can be directly connected)
    Maximum load of socket 12 KW(total of 4 sockets)
    Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
    Water discharge way Magnetic chemical pump strong discharge
    Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
    Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
    Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
    Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
    Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
    Speed deviation of surface air Not higher than 10%
    The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
    Noise Within 55 decibels
    Flow display White smoke can pass through the exhaust outlet, no overflow.
    Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
    Resistance of exhaust cabinet Less than 160 pa
    Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
    Water consumption Less than 3.2L/ h Less than 4.0L/ h
    Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
    Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)

    3. Type of Fume Hood

    Laboratory fume hoods can be fabricated from different materials and include specific surface types, such as stainless steel, fiberglass, PVC or even polypropylene.

    Chemical fume hoods are a mainstay for most research and educational labs. They protect users from chemical and radiological exposure. Ideal if you plan on conducting experiments that use toxic or volatile chemicals to lower the chances of inhalation.

    Laminar flow hoods protect the samples from contamination. They do not offer lab personnel any protection; thus, you must not use them when working with toxic or infectious chemicals.

    Demonstration or educational hoods: These are optimized for teaching. An example is the double-faced fume hoods, which have entrances on both sides, allowing for 360-degree viewing.

    Biological Safety Cabinets (BSCs) have a different application and do not fall within the fume hood category. They are, however, a must-have for labs that handle viral microbes and infectious diseases.

    4. Detailed Photos


     

    Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof
    Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof
     
    Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof
    Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof
    Acid & Alkali Resistant Corrosion Resistance Lab Chemical Fume Hood Explosion Proof

    5. FAQ

    The process of researching and purchasing the right fume hood  for your laboratory can seem overwhelming and choosing the right one is crucial to ensuring safety from dangerous chemicals and vapors in your lab. 

    Here are a few important questions and considerations to help you choose the right fume hood for your lab.

    1. What type of work are you conducting inside your fume hood
      • Review your experiment methods and material lists.
        • Document which chemicals, or solvents, you will be using and the concentration of each chemical
        • Determine the evaporation rate of the chemicals.
          • Chemical solvents evaporate at different rates and if not accounted for, can overwhelm the fume hood by evaporating at a rate too fast for the fume hood to ventilate
             
    2. What size lab hood do you need?
      • Will you have equipment inside your laboratory fume hood?
      • How large is the equipment?
        • If your application involves extra-large equipment, such as drum containers, a walk-in fume hood might be appropriate.
      • How many people will be working simultaneously under the fume hood?
        • Depth - Consider buffer space.
        • Perform your work at least 6 inches behind the sash to ensure a safety buffer zone is maintained.
        • Height - Make sure your lab has ample height clearance for a larger bench top or floor mounted fume hood.
           
    3. How will fumes be filtered and exhausted?
      • Duct or ductless
        • ducted fume hood connects to a remote blower of the facility HVAC system to safely remove noxious or dangerous chemicals from the work area.
        • ductless fume hood contains an integral blower, carbon filters to capture chemical vapors and, if required, HEPA/ULPA particle filters to allow recirculation of exhaust air.
           
    4. Which ventilation system should you use for a ducted fume hood?
      • A ducted fume hood has two (2) options for ventilation control, constant air volume (CAV) and variable air volume (VAV).
        • To choose between CAV and VAV, you will need to take into consideration both operating duration and budget.
           
    5. What are the Operating costs and install of a fume hood?
      • Operating Costs:
        • Ductless fume hood = the majority of operating costs for a ductless fume hood will come from filter charges.
        • Ducted fume hood = The cost of operating a ducted fume hood can be calculated as a function of how much air the blower is exhausting. Thus, the operating cost increases as a function of volume of air (DFM) being moved.
           
    6. What accessories will you need for your fume hood?
      • Fume hood accessories include base cabinets, light fixtures, airflow monitors, electrical outlets, cup sinks, and service fixtures for water, vacuum, or gas.

    6. What Type of Fume Hood Fan or Blower Do You Need?

    Which type of blower you need depends on the intended use. If you are venting non-toxic materials, for example, you could use a steel blower coated with epoxy.

    If the purpose is to mix acids, you will need an acid-resistant blower. PVC is often the best material choice for perchloric acids and other corrosive operations.

    Where the chemicals in your lab are moderately or highly corrosive, fiberglass is also a good option. If your work is volatile, there are even blowers with explosion-proofing and those that are resistant to sparks.

    These fume hood blowers will often come with an enclosed motor that ensures fumes in the air stream won't encounter a spark or touch the motor.

    If there's any chance of fumes in your lab catching on fire, spark resistance should prioritize.

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier