Basic Info.
Function
Exhaust, Velocity Control
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Product Name
Chemical Fume Hood
Interior Baffle
Ceramic/Ceramic Fiber
Liner Material
Ceramic Fiber
Sash
Tempered Glass/Laminated Glass
Cabinet
Multi-Layer Solid Wood
Application
Environment/Institute/Biology Lab/Chemical Lab
Transport Package
Standard Export Wooden Case Packing
Specification
1500*1205*2400 MM
Product Description
Product Description
A fume hood (sometimes called a fume cupboard or fume closet) is a type of local ventilation device that is designed to limit exposure to hazardous or toxic fumes, vapors or dusts.
A fume hood is typically a large piece of equipment enclosing five sides of a work area, the bottom of which is most commonly located at a standing work height.
Two main types exist, ducted and recirculating (ductless). The principle is the same for both types: air is drawn in from the front (open) side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room. This is used to:
-protect the user from inhaling toxic gases (fume hoods, biosafety cabinets, glove boxes)
-protect the product or experiment (biosafety cabinets, glove boxes)
-protect the environment (recirculating fume hoods, certain biosafety cabinets, and any other type when fitted with appropriate filters in the exhaust airstream)
Secondary functions of these devices may include explosion protection, spill containment, and other functions necessary to the work being done within the device.
Product Parameters
Model Parameters | YT-1500A | YT-1500B | YT-1500C | YT-1800A | YT-1800B | YT-1800C |
Size (mm) | 1500(W)*865(D)*2400(H) | 1800(W)*1205(D)*2400(H) |
Worktop Size (mm) | 1260(W1)*795(D1)*1100(H1) | 1560(W1)*795(D1)*1100(H1) |
Worktop | 20+6mm Ceramic | 20+6mm Ceramic | 12.7mm Solid Physiochemical Board | 20+6mm Ceramic | 20+6mm Ceramic | 12.7mm Solid Physiochemical Board |
Liner | 5mm Ceramic Fibre | 5mm Compact Laminate | 5mm Compact Laminate | 5mm Ceramic Fibre | 5mm Compact Laminate | 5mm Compact Laminate |
Diversion Structure | Back Absorption |
Control System | Touch-Tone Control Panel (LED Screen) |
Input Power | 220V/32A |
Fan Power | Less than 2.8 A |
Socket Max. Load | 5KW |
Faucet | 1 Set |
Drainage Mode | Natural Fall |
Storage | Double-Lock, Corrosion-Resistant, Damp-proof, Multi-layer Solid Wood with Mobile Wheel |
Application | Indoor No-blast, 0-40 ºC |
Application Field | Organic Chemical Experiment |
Face Velocity Control | Manual Control |
Average Face Velocity | 0.3-0.5 m/s Exhaust: 720-1200m³/h | 0.3-0.5 m/s Exhaust:900- 1490m³/h |
Face Velocity Deviation | Less than 10% |
Average Illumination | Less than 500 Lux |
Noise | Within 55 dB |
Exhaust Air | No Residue |
Safety Test | In Accord with International Standard |
Resistance | Less than 70Pa |
Add Air Function | Distinctive Structure (Need Exclusive Add Air System) |
Air Flow Control Valve | Dia. 250mm Flange Type Anti-Corrosion Control Valve | Dia. 315mm Flange Type Anti-Corrosion Control Valve |
More About the Fume Hood
Avoid Common Fume Hood Mistakes
Fume hoods are very effective safety devices when used correctly. However, no matter how well a fume hood is designed, it won't be effective unless proper laboratory safety measures are taken. Common mistakes when using a fume hood can be detrimental to the user's personal safety and the safety of everyone else around them.
Raising the sash too high
The user should never place their head inside the hood opening. For vertical rising sashes, keep the sash below your face; for horizontal sliding sashes, keep the sash in front of you and work around the side.
Keeping the sash at operating height will maintain the airflow. The sash determines the airflow of the fume hood. Although the sash position doesn't control the volume of air that passes through the hood, it does control the velocity, which influences chemical vapor capture. Raising the sash reduces air velocity, allowing contaminants to spill into the room.
When the fume hood is not in use, the sash should be kept closed. Fume hoods are designed for the sashes to be kept closed. The airfoil sill at the base of the hood will still allow air to be pulled in even with the sash fully closed.
Detailed Photos
Fume Hood Maintenance
• Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.
• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.• Fume hoods should be certified, at least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies have shown that face velocity is not a good predictor of fume hood leakage. • Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.• Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from exposure to vapors, aerosols, toxic materials, odorous, and other harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.FAQ
6 Questions to Ask When Buying a Fume Hood:
-Which chemicals will you use within the hood?
-Is a ducted or ductless hood best suited to your needs and available space?
-Where will you place the fume hood in the lab? Consider workflows, access to external exhaust systems, and competing air patterns.
-What size fume hood will best suit your needs? Be sure to consider what (if any) equipment will be enclosed in the hood.
-Are any service fixtures or accessories such as airflow monitors, electrical outlets, water, or gas fixtures required?
-Are base cabinets for acid, solvent, or non-chemical storage required?
Address:
No. 11, 11th Floor, Unit 2, Building 2, No. 1, Section 1, Huayang Huafu Avenue, Tianfu New District, Chengdu, Sichuan, China
Business Type:
Manufacturer/Factory
Business Range:
Construction & Decoration, Electrical & Electronics, Furniture, Health & Medicine, Industrial Equipment & Components, Instruments & Meters, Office Supplies, Security & Protection, Sporting Goods & Recreation
Management System Certification:
ISO 9001
Company Introduction:
Chengdu Ample Import and Export Co., Ltd. is a professional solution-oriented supplier aiming to be one of the leading Exporter and Manufacturer of Laboratory furniture such as lab fume hoods, lab storage cabinets, and benches, Office chairs, with well-equipped testing facilities and strong technical force.
Our products are extensively used in many industry fields with a wide range, good quality, reasonable prices, and advanced designs.
One of the Ample factories specializes in laboratory protective products to meet the requirements of different kinds of laboratory experiments. We also supply customers with China′s Top-quality medical devices at the factory-direct price.
We both provide customized products and OEM service for our all products.
Our company tenet is Top in Quality, Best in Service.
Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs.
We sincerely welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!