Once a fume hood is installed and set up in an actual laboratory room, it is recommended that tracer gas containment tests be conducted to determine the appropriate face velocity necessary to maintain a desirable level of containment. Once the average face velocity that will provide the desired containment level is determined, that face velocity can serve as a reasonable benchmark for safe fume hood operation.
This assumes that the room conditions essentially remain as they were when the fume hood was tested and that the fume hood users follow safe fume hood working practices. Note that since a fume hood is not an airtight enclosure, perfect or 100% containment is not generally attainable or even necessary.
The level of containment that is necessary should be established by facility personnel who are responsible for worker safety in consideration of the hazard level posed by the chemicals. If the chemicals or substances that will be present are so toxic or hazardous that 100% or near 100% containment is required, than an airtight glove box should be utilized rather than a fume hood.
Model Specification | WJ-1500A | WJ-1500B | WJ-1800A | WJ-1800B |
External dimensions of equipment(mm) | 1500(W)*1205 (D) *2400 (H) | 1800(W)*1205 (D) *2400 (H) | ||
Dimension of works pace (mm) | 1260(W1)*780(D1) *1100 (H1) | 1560(W1)*780(D1) *1100 (H1) | ||
Panel material | 20+6mm thick butterfly ceramics | |||
Material of internal lining board | 5mm thick ceramic fiber board | |||
Diversion structure | Lower air return | |||
Control system | Button control panel (LCD panel) | |||
PH value control | The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump. | |||
Input power | Three-phase five-wire 380V/50A | |||
Current for air fan | Not over 2.8A(380V or 220V can be directly connected) | |||
Maximum load of socket | 12 KW(total of 4 sockets) | |||
Water tap | 1 set (remote control valve + water nozzle) | No | 1 set (remote control valve + water nozzle) | No |
Water discharge way | Magnetic chemical pump strong discharge | |||
Using environment | For non-explosion indoor use, within 0-40 degrees Celsius. | |||
Applicable fields | Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc. | |||
Ways of Purification | Spray sodium hydroxide solution, no less than 8 cubic meters/hour | Spray sodium hydroxide solution.no less than 12 cubic meters/ hour | ||
Ways of surface air speed control | Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door) | |||
Average surface air speed | 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) | 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm) | ||
Speed deviation of surface air | Not higher than 10% | |||
The average intensity of illumination | Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable. | |||
Noise | Within 55 decibels | |||
Flow display | White smoke can pass through the exhaust outlet, no overflow. | |||
Safety inspection | No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test. | |||
Resistance of exhaust cabinet | Less than 160 pa | |||
Power consumption | Less than 1.0kw/h (excluding power consumption of fans and external instruments) | Less than 1.2kw/h (excluding power consumption of fans and external instruments) | ||
Water consumption | Less than 3.2L/ h | Less than 4.0L/ h | ||
Performance of wind compensation | With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory) | |||
Air volume regulating valve | 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator) |
Manufacturers normally test their fume hoods without chemicals or laboratory equipment inside the hood (except for the tracer gas ejector). In actual use, a fume hood is likely to contain all sorts of apparatus and equipment, including: support racks, beakers, hoses, heaters, chemical containers,analyzers, etc.
Some items may be quite large and positioned in a way that adversely affects the internal airflow pattern that is necessary for optimum fume containment. Experiments or chemical processes may give off substantially greater amounts of fumes than the quantity of tracer gas used in the ASHRAE 110 test.
Also, the actual chemical fumes generated may be of much different buoyancy than sulfur hexafluoride tracer gas and, therefore, behave differently. Heaters and electrical equipment within a fume hood's interior generate convection air currents. All of these factors-either individually or combined-usually have an adverse effect on fume containment especially in comparison to a nearly empty fume hood tested under optimum room conditions.
• Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.
• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.6 Questions to Ask When Buying a Fume Hood:
-Which chemicals will you use within the hood?
-Is a ducted or ductless hood best suited to your needs and available space?
-Where will you place the fume hood in the lab? Consider workflows, access to external exhaust systems, and competing air patterns.
-What size fume hood will best suit your needs? Be sure to consider what (if any) equipment will be enclosed in the hood.
-Are any service fixtures or accessories such as airflow monitors, electrical outlets, water, or gas fixtures required?
-Are base cabinets for acid, solvent, or non-chemical storage required?