Corrosion Resistance Laboratory Fume Hood with Movable Sash
Contact Supplier
Product Highlights
- Corrosion & Acid Resistance: Constructed with stainless steel and ceramic materials for acid, alkali, and corrosion resistance.
- Customizable Design: Product dimensions, worktop material, and liner material can be customized to specific needs.
- Advanced Control System: Features LCD panel, PH value monitoring, and manual control via acid/alkali pumps.
- High Safety Standards: Explosion-proof, fireproof, and designed to prevent turbulence and pressure shifts.
- Energy Efficient Operation: Low power consumption under 1.2kw/h and water usage under 4.0L/h.
- Adjustable Illumination: Features adjustable LED lamps with over 700 Lux intensity, white and UV-free yellow options.
- Low Noise Operation: Operates at noise levels within 55 decibels for a quiet laboratory environment.
- Precise Airflow Control: Maintains surface air speed between 0.6-0.8 m/s with less than 10% deviation.
Product Attributes
- Customization
- Available
- Material
- Stainless Steel
- Type
- Slit Type
- Model NO.
- WJ-1500A
- Function
- Exhaust, Velocity Control
- Feature
- Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
- Hood Type
- Standard
- Color
- Grey
- Customized
- Customized
- Condition
- New
- Product Name
- Chemical Fume Hood
- Worktop
- 20+6 mm Ceramic
- Liner Material
- Ceramic Fiber Board
- Input Power
- 380V/50A
- Face Velocity
- 0.4-0.6 M/S
- Application
- Environment/Institute/Biology Lab/Chemical Lab
- Transport Package
- Standard Export Wooden Case Packing
- Specification
- 1500*1205*2400 MM
- Trademark
- Ample
- Origin
- Chengdu, China
- HS Code
- 8414809090
- Production Capacity
- 200 Set/Month
- Package Size
- 1900.00cm * 900.00cm * 2100.00cm
- Package Gross Weight
- 500.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of Corrosion Resistance Laboratory Fume Hood with Movable Sash
Find Similar Products
Product Description
Fume hoods and accessories represent one of the largest expenditures that a laboratory manager faces. The cost of air filtration does not end at the initial purchase price of a fume hood. Construction of ductwork and placement of utilities may be a one-time expense, however the ongoing cost of power and the increased HVAC load on the facility can be significant.
Traditional "ducted" fume hoods are connected to existing facility ductwork and pull contaminated air through the hood and direct it outside the facility and into the atmosphere. Ducted fume hoods can be filtered or unfiltered depending on the design and application. Ductless fume hoods contain filters which clean contaminated air and recirculate it directly back into the laboratory. No additional ductwork is required to exhaust air to the outside. Ductless fume hoods provide the same filtration capabilities as ducted hoods, but are easier to install, have lower initial installation costs and can be highly efficient.
| Model Specification | WJ-1500A | WJ-1500B | WJ-1800A | WJ-1800B |
| External dimensions of equipment(mm) | 1500(W)*1205 (D) *2400 (H) | 1800(W)*1205 (D) *2400 (H) | ||
| Dimension of works pace (mm) | 1260(W1)*780(D1) *1100 (H1) | 1560(W1)*780(D1) *1100 (H1) | ||
| Panel material | 20+6mm thick butterfly ceramics | |||
| Material of internal lining board | 5mm thick ceramic fiber board | |||
| Diversion structure | Lower air return | |||
| Control system | Button control panel (LCD panel) | |||
| PH value control | The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump. | |||
| Input power | Three-phase five-wire 380V/50A | |||
| Current for air fan | Not over 2.8A(380V or 220V can be directly connected) | |||
| Maximum load of socket | 12 KW(total of 4 sockets) | |||
| Water tap | 1 set (remote control valve + water nozzle) | No | 1 set (remote control valve + water nozzle) | No |
| Water discharge way | Magnetic chemical pump strong discharge | |||
| Using environment | For non-explosion indoor use, within 0-40 degrees Celsius. | |||
| Applicable fields | Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc. | |||
| Ways of Purification | Spray sodium hydroxide solution, no less than 8 cubic meters/hour | Spray sodium hydroxide solution.no less than 12 cubic meters/ hour | ||
| Ways of surface air speed control | Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door) | |||
| Average surface air speed | 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) | 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm) | ||
| Speed deviation of surface air | Not higher than 10% | |||
| The average intensity of illumination | Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable. | |||
| Noise | Within 55 decibels | |||
| Flow display | White smoke can pass through the exhaust outlet, no overflow. | |||
| Safety inspection | No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test. | |||
| Resistance of exhaust cabinet | Less than 160 pa | |||
| Power consumption | Less than 1.0kw/h (excluding power consumption of fans and external instruments) | Less than 1.2kw/h (excluding power consumption of fans and external instruments) | ||
| Water consumption | Less than 3.2L/ h | Less than 4.0L/ h | ||
| Performance of wind compensation | With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory) | |||
| Air volume regulating valve | 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator) | |||
The biggest challenge with fume hood performance is that users usually cannot see the hazards-most are invisible and odorless. Therefore, there is no easy way to know if your fume hood is working properly and protecting you. Many think that face velocity, which is defined as the speed of the air entering the sash opening, is an indication of safety. The ANSI/AIHA Z9.5 Laboratory Ventilation states: "Face velocity had been used historically as the primary indicator of laboratory hood performance for several decades. However, studies involving large populations of laboratory fume hoods tested using a containment-based test like the ANSI/ASHRAE Standard 110, 'Method of Testing the Performance of Laboratory Fume Hoods,' reveal that face velocity alone is an inadequate indicator of hood performance." In fact, most hoods that fail containment testing have acceptable face velocity readings.
So, what causes loss of containment in a fume hood? The two biggest causes are turbulence and pressure shifts (room pressure versus fume chamber pressure).
Air is a liquid; it follows the laws of fluid dynamics. It flows from high pressure to low pressure. Picture a smooth flowing river, the surface is only moved by wind. Add lots of boulders, and now there are rapids. The smooth flowing river has transformed into a raging obstacle course. People do the same in and around fume hoods. Their actions create turbulence in the airflow that increases the chance of loss of containment.
• Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.
• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.• Fume hoods should be certified, at least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies have shown that face velocity is not a good predictor of fume hood leakage.
• Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.
• Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from exposure to vapors, aerosols, toxic materials, odorous, and other harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.
6 Questions to Ask When Buying a Fume Hood:
-Which chemicals will you use within the hood?
-Is a ducted or ductless hood best suited to your needs and available space?
-Where will you place the fume hood in the lab? Consider workflows, access to external exhaust systems, and competing air patterns.
-What size fume hood will best suit your needs? Be sure to consider what (if any) equipment will be enclosed in the hood.
-Are any service fixtures or accessories such as airflow monitors, electrical outlets, water, or gas fixtures required?
-Are base cabinets for acid, solvent, or non-chemical storage required?
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR238059". Items marked "" are certified.
Company Profile
Chengdu Ample Import and Export Co., Ltd. is a professional solution-oriented supplier aiming to be one of the leading Exporter and Manufacturer of Laboratory furniture such as lab fume hoods, lab storage cabinets, and benches, Office chairs, with well-equipped testing facilities and strong technical force.
Our products are extensively used in many industry fields with a wide range, good quality, reasonable prices, and advanced designs.
One of the Ample factories specializes in laboratory protective products to meet the requirements of different kinds of laboratory experiments. We also supply customers with China's Top-quality medical devices at the factory-direct price.
We both provide customized products and OEM service for our all products.
Our company tenet is Top in Quality, Best in Service.
Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs.
We sincerely welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
About Our Factory & Business Background
- Address
- No. 11, 11th Floor, Unit 2, Building 2, No. 1, Section 1, Huayang Huafu Avenue, Tianfu New District, Chengdu, Sichuan, China
- Terms of Payment
- LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, EXW, CIF
- Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2019-07-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- Which chemicals will you use within the hood?
- The hood is suitable for inorganic chemistry experiments, food, medicine, electronics, environment, metallurgy, and mining applications.
- Is a ducted or ductless hood best suited to your needs?
- Ducted hoods exhaust air outside, while ductless hoods filter and recirculate air. The choice depends on your facility's ductwork and space.
- Where will you place the fume hood in the lab?
- Consider workflows, access to external exhaust systems, and competing air patterns to ensure optimal performance and safety.
- What size fume hood will best suit your needs?
- Consider the equipment to be enclosed. Available models include 1500mm and 1800mm widths with specific depth and height dimensions.
- Are any service fixtures or accessories required?
- Options include airflow monitors, electrical outlets, water taps, and gas fixtures, which can be customized based on requirements.
- Are base cabinets for acid, solvent, or non-chemical storage required?
- Base cabinets can be added for storing acids, solvents, or non-chemical items to enhance laboratory organization and safety.
Send your message to this supplier
People who viewed this also viewed
-
US$4,400.00-5,080.00 / Piece
-
US$4,500.00-6,500.00 / Set
-
US$4,500.00-6,500.00 / Set
-
US$4,500.00-8,500.00 / Set
Find Similar Products By Category
- Supplier Homepage
- Products
- Duct Fume Hood
- Corrosion Resistance Laboratory Fume Hood with Movable Sash
Related Categories
Hot Searches
- Furniture Equipment
- Supermarket Equipment Factories
- Store Equipment Factories
- Portable Bed Factories
- New Fume Hood
- Steel Fume Hood
- Lab Fume Hood
- Fume Hood For Laboratory
- Bench Fume Hood Laboratory
- Fume Hood Bulkbuy