Energy-Saving Explosion Proof Chemical Fume Hood for Hospital
Contact Supplier
Product Highlights
- Explosion Proof Safety: Designed for safe handling of hazardous materials with explosion-proof features.
- Corrosion Resistance: Constructed with stainless steel and ceramic materials for acid, alkali, and heat resistance.
- Velocity Control: Features manual control for surface air speed ranging from 0.6-0.8 m/s.
- Customizable Options: Product name, worktop, liner material, and input power can be customized.
- Energy Efficient: Low power consumption under 1.0-1.2kw/h and water usage under 3.2-4.0L/h.
- Advanced Purification: Uses spray sodium hydroxide solution for purification with high flow rates.
- Quiet Operation: Noise level maintained within 55 decibels for a comfortable lab environment.
- Bright Illumination: Standard white and UV-free yellow LED lamps with adjustable illumination.
Product Attributes
- Customization
- Available
- Material
- Stainless Steel
- Type
- Bypass Type
- Model NO.
- WJ-1500A
- Function
- Exhaust, Velocity Control
- Feature
- Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
- Hood Type
- Standard
- Color
- Grey
- Customized
- Customized
- Condition
- New
- Product Name
- Benchtop Fume Hood
- Worktop
- 20+6 mm Ceramic
- Liner Material
- Ceramic Fiber Board
- Input Power
- 380V/50A
- Face Velocity
- 0.4-0.6 M/S
- Application
- Environment/Institute/Biology Lab/Chemical Lab
- Transport Package
- Standard Export Wooden Case Packing
- Specification
- 1500*1205*2400 MM
- Trademark
- Ample
- Origin
- Chengdu, China
- HS Code
- 8414809090
- Production Capacity
- 200 Set/Month
- Package Size
- 1900.00cm * 900.00cm * 2100.00cm
- Package Gross Weight
- 500.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of Energy-Saving Explosion Proof Chemical Fume Hood for Hospital
Find Similar Products
Product Description
A laboratory fume hood is a ventilated enclosure where hazardous materials can be handled safely. The purpose of the hood is to contain contaminants and prevent their escape into the laboratory. This is accomplished by drawing (by air flow) contaminants within the hood's work area away from the user thereby preventing and minimizing inhalation and contact with hazardous materials.
To create airflow into the hood, an exhaust blower "pulls" air from the laboratory room into and through the hood and exhaust system . A baffle, airfoil, and other aerodynamically designed components control the patterns of air moving into and through the hood.
Fume Hoods must be located away from heavy traffic aisles and doorways so that persons exiting the lab do not have to pass in front of the fume hood. The potentially dangerous portion of an experiment is usually conducted in a fume hood. Many lab fires and explosions originate in fume hood and a fume hood located adjacent to a path of egress could trap someone in the lab.
There must be two exits from rooms where new fume hoods are to be installed. If this is not feasible, the fume hood must be situated on the side of the room furthest from the door. A fire or chemical hazard, both of which often start in a fume hood, can render an exit impassible. For this reason, all labs with fume hoods are required to maintain two unblocked routes of egress.
| Model Specification | WJ-1500A | WJ-1500B | WJ-1800A | WJ-1800B |
| External dimensions of equipment(mm) | 1500(W)*1205 (D) *2400 (H) | 1800(W)*1205 (D) *2400 (H) | ||
| Dimension of works pace (mm) | 1260(W1)*780(D1) *1100 (H1) | 1560(W1)*780(D1) *1100 (H1) | ||
| Panel material | 20+6mm thick butterfly ceramics | |||
| Material of internal lining board | 5mm thick ceramic fiber board | |||
| Diversion structure | Lower air return | |||
| Control system | Button control panel (LCD panel) | |||
| PH value control | The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump. | |||
| Input power | Three-phase five-wire 380V/50A | |||
| Current for air fan | Not over 2.8A(380V or 220V can be directly connected) | |||
| Maximum load of socket | 12 KW(total of 4 sockets) | |||
| Water tap | 1 set (remote control valve + water nozzle) | No | 1 set (remote control valve + water nozzle) | No |
| Water discharge way | Magnetic chemical pump strong discharge | |||
| Using environment | For non-explosion indoor use, within 0-40 degrees Celsius. | |||
| Applicable fields | Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc. | |||
| Ways of Purification | Spray sodium hydroxide solution, no less than 8 cubic meters/hour | Spray sodium hydroxide solution.no less than 12 cubic meters/ hour | ||
| Ways of surface air speed control | Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door) | |||
| Average surface air speed | 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) | 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm) | ||
| Speed deviation of surface air | Not higher than 10% | |||
| The average intensity of illumination | Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable. | |||
| Noise | Within 55 decibels | |||
| Flow display | White smoke can pass through the exhaust outlet, no overflow. | |||
| Safety inspection | No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test. | |||
| Resistance of exhaust cabinet | Less than 160 pa | |||
| Power consumption | Less than 1.0kw/h (excluding power consumption of fans and external instruments) | Less than 1.2kw/h (excluding power consumption of fans and external instruments) | ||
| Water consumption | Less than 3.2L/ h | Less than 4.0L/ h | ||
| Performance of wind compensation | With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory) | |||
| Air volume regulating valve | 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator) | |||
•Fume hoods should be located within the laboratory to avoid cross currents at the fume hood face due to heating cooling, or ventilation supply or exhaust diffusers.Cross currents outside a hood can nullify or divert air flow onto a hood, negatively affecting its capture ability.
•Sufficient makeup air must be available within the laboratory to permit fume hoods to operate at their specified face velocities. A fume hood exhausts a substantial amount of air. Therefore, additional makeup air must be brought onto the room to maintain a proper air balance.
• Windows in labs that have fume hoods must be fixed closed. Breezes coming in through open lab windows can adversely affect the proper functioning of the hood. Turbulence caused by these wind currents can easily bring the contaminated air inside the hood back into the laboratory.
•Safety devices such as deluge showers, eye wash stations, fire extinguishers, and fire blankets should be located convenient to the fume hood operating personnel.
•Fume hoods shall not have an on/off control accessible in the laboratory, unless the lab has an alternate exhaust ventilation system or the exhaust is being filtered through a charcoal or HEPA filter. Fume hoods are an integral part of the entire laboratory's air balancing system which must be maintained. Labs must be maintained under positive pressure and when a fume hood is turned off the lab can develop positive pressure.
Close The Sash
When an employee is not working inside the hood, the sash should remain closed.
Avoid Storing Chemicals In The Hood
Employees should never store any chemicals inside the hood when it is not in use. Chemicals should instead be stored in industrial furniture cabinets equipped to hold hazardous chemicals. However, large equipment can be stored in the hood as long as it is on top of blocks to allow air flow under the equipment.
Report Any Problems
Promptly report any issues you have experienced with the fume hood to a supervisor. It is important that a supervisor takes this fume hood out of service until it can be repaired to ensure the safety of employees.
What should do if accident accurs?
No one likes to think that an accident may occur. However, if it does, it is always better to be prepared and know what the proper response looks like.
The most important step to take in the immediate aftermath of a fume hood accident is its response. Take any and all actions to safeguard people working in the lab first and foremost. That may include putting out any fires, containing spills, evacuating the area, attending to the injured and contacting emergency services.
After the accident, an investigation must immediately begin. This will prevent important data from being lost and witness forgetting important details. By determining whether safety procedures were followed and whether equipment worked as it should have, new protocols can be put into place to prevent similar future accidents.
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR238059". Items marked "" are certified.
Company Profile
Chengdu Ample Import and Export Co., Ltd. is a professional solution-oriented supplier aiming to be one of the leading Exporter and Manufacturer of Laboratory furniture such as lab fume hoods, lab storage cabinets, and benches, Office chairs, with well-equipped testing facilities and strong technical force.
Our products are extensively used in many industry fields with a wide range, good quality, reasonable prices, and advanced designs.
One of the Ample factories specializes in laboratory protective products to meet the requirements of different kinds of laboratory experiments. We also supply customers with China's Top-quality medical devices at the factory-direct price.
We both provide customized products and OEM service for our all products.
Our company tenet is Top in Quality, Best in Service.
Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs.
We sincerely welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
About Our Factory & Business Background
- Address
- No. 11, 11th Floor, Unit 2, Building 2, No. 1, Section 1, Huayang Huafu Avenue, Tianfu New District, Chengdu, Sichuan, China
- Terms of Payment
- LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, EXW, CIF
- Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2019-07-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What should be done if an accident occurs?
- Safeguard people first by putting out fires, containing spills, evacuating, attending to injured, and contacting emergency services. Then, conduct an immediate investigation to determine if safety procedures were followed and implement new protocols.
- What are the main applications for this fume hood?
- It is suitable for inorganic chemistry experiments, food, medicine, electronics, environment, metallurgy, and mining industries.
- What is the input power requirement?
- The standard input power is three-phase five-wire 380V/50A, but this can be customized.
- How is the air speed controlled?
- It uses manual control through an electric air valve to adjust exhaust air volume or by adjusting the height of the moving door.
- What is the average surface air speed?
- The average surface air speed is 0.6-0.8 m/s.
- What are the payment terms?
- Payment can be made via LC, T/T, PayPal, Western Union, Small-amount payment, or Money Gram.
- What is the lead time for delivery?
- Peak season lead time is one month, while off-season lead time is within 15 workdays.
Send your message to this supplier
People who viewed this also viewed
-
US$4,400.00-5,080.00 / Piece
-
US$4,500.00-6,500.00 / Set
-
US$4,500.00-6,500.00 / Set
-
US$4,500.00-8,500.00 / Set
Find Similar Products By Category
- Supplier Homepage
- Products
- Acid Digestion Fume Hood
- Energy-Saving Explosion Proof Chemical Fume Hood for Hospital
Related Categories
Hot Searches
- China Cabinet Factories
- Cabinet Doors Factories
- Cabinet Hardware Factories
- Steel Cabinet Factories
- New Fume Hood
- Steel Fume Hood
- Lab Fume Hood
- Fume Hood For Laboratory
- Bench Fume Hood Laboratory
- Top 10 Cabinet
- Cabinet Trends
- Chemical Fume Hood Bulkbuy