Acid & Alkali Resistant High Performance Fume Hood for Education

Product Details
Customization: Available
Material: Stainless Steel
Type: Bypass Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Acid & Alkali Resistant High Performance Fume Hood for Education
  • Acid & Alkali Resistant High Performance Fume Hood for Education
  • Acid & Alkali Resistant High Performance Fume Hood for Education
  • Acid & Alkali Resistant High Performance Fume Hood for Education
  • Acid & Alkali Resistant High Performance Fume Hood for Education
  • Acid & Alkali Resistant High Performance Fume Hood for Education
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Our Advantages
  • Detailed Photos
  • Usage Attention
  • Fume Hood Maintenance
Overview

Basic Info.

Model NO.
WJ-1800A
Function
Exhaust, Velocity Control
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
Grey
Customized
Customized
Condition
New
Product Name
Fume Hood Price
Worktop
20+6 mm Ceramic
Liner Material
Ceramic Fiber Board
Input Power
380V/50A
Face Velocity
0.4-0.6 M/S
Application
Environment/Institute/Biology Lab/Chemical Lab
Transport Package
Standard Export Wooden Case Packing
Specification
1800*1205*2400 MM
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Packaging & Delivery

Package Size
1900.00cm * 900.00cm * 2100.00cm
Package Gross Weight
360.000kg

Product Description

 
Product Description

Fume hoods, or fume cupboards, work to ensure the safety of lab personnel while working with hazardous materials by continuously delivering airflow away from the user. When used properly, fume hoods can prevent users and the environment from toxic gases, explosions, and spills.

Ducted fume hoods have a base, work surface, hood, blower and ducting that carries the air outside of the building. The engineer of the heating, ventilation and air-conditioning (HVAC) system needs to determine if your room has enough air to provide the necessary volume of ventilation to the hood.

Ductless fume hoods operate off a carbon filter system that recirculates filtered air into your building. Ductless hoods are often referred to as re-circulating range hoods. They filter the air and then return the clean air back into the workspace. They are self-contained filtered laboratory enclosures. Their primary features are mobility, they save energy, are easy to install and cheaper because no ductwork is required.

Product Parameters
 
                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Our Advantages

Ducted fume hoods are considered safest for workers in laboratories, and its often the easiest for employers to maintain. Many universities ONLY allow ducted fume hoods in their facilities to maintain worker and student safety.

Advantages and Disadvantages of Ducted Fume Hoods

Advantages Disadvantages
Safer for lab workers More expensive
Can handle a wide range of chemicals More difficult to install
Easy to operate and maintain Stationary in the lab
Exhaust system keeps contamination outside lab More difficult to move or relocate
  Uses more energy

The disadvantage is that workers are at a greater risk of chemical exposure, filter maintenance is required, they can be noisy due to the internal blower and there are limited applications for filter options.

Ductless fume hoods are ideal for labs that require mobility, handle light to moderate chemical loads and are looking for a cost-effective option from both an installation and operational perspective.

Advantages and Disadvantages of Ductless Fume Hoods
 
Advantages Disadvantages
Less expensive Handles Limited chemicals
Easy to install Need to replace filters 
Mobile in the lab Not as effective at removing chemical fumes
Easily moved or relocated Not for constant use
Use less energy  
Detailed Photos
      
Acid & Alkali Resistant High Performance Fume Hood for Education
Acid & Alkali Resistant High Performance Fume Hood for Education
 
Acid & Alkali Resistant High Performance Fume Hood for Education
Acid & Alkali Resistant High Performance Fume Hood for Education
 
Usage Attention

If you work on the inside of the ductwork or on the fans, follow this procedure :

-Notify the group that owns the hood five days before the work is to  begin. Tell them that they won't be able to use the hood during the  work. The lab must also take every container out of the hood for the duration of the shutdown.

 
-Notify the Environmental Safety Compliance Officer (ESCO) and the Facilities Manager of the shutdown. The ESCO must verify that it has been cleaned and is safe to perform work on it.
 
-Following the standard lockout procedure, lock off the fan and lock the sashes closed on all the fume hoods connected to the fan and ductwork.
 
-Steam clean, pressure wash or clean with warm soapy water and a brush any parts that might be contacted during the work. Collect all the wash water for disposal if hazardous.

The person doing the cleaning must wear chemical splash protection during the procedure, including:
• Lab coat or apron,
• Disposable latex or neoprene gloves, and
• Full or half face respirator and splash goggles. The respirators should have high efficiency particulate air filters (HEPA).
Fume Hood Maintenance

Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.

• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.

 Fume  hoods should  be certified, at  least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies  have shown that face velocity is not a good predictor of fume hood leakage.

• Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.

 Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from  exposure to vapors,  aerosols, toxic  materials,  odorous,  and  other  harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier