Acid & Alkali Resistant Laboratory Fume Hood with Movable Sash

Product Details
Customization: Available
Material: Stainless Steel
Type: Slit Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Acid & Alkali Resistant Laboratory Fume Hood with Movable Sash
  • Acid & Alkali Resistant Laboratory Fume Hood with Movable Sash
  • Acid & Alkali Resistant Laboratory Fume Hood with Movable Sash
  • Acid & Alkali Resistant Laboratory Fume Hood with Movable Sash
  • Acid & Alkali Resistant Laboratory Fume Hood with Movable Sash
  • Acid & Alkali Resistant Laboratory Fume Hood with Movable Sash
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • More About the Fume Hood
  • Detailed Photos
  • Fume Hood Maintenance
  • FAQ
Overview

Basic Info.

Model NO.
WJ-1500B
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
Grey
Customized
Customized
Condition
New
Product Name
Laboratory Fume Hood
Worktop
20+6 mm Ceramic
Liner Material
Ceramic Fiber Board
Input Power
380V/50A
Face Velocity
0.4-0.6 M/S
Application
Environment/Institute/Biology Lab/Chemical Lab
Transport Package
Standard Export Wooden Case Packing
Specification
1500*1205*2400 MM
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Packaging & Delivery

Package Size
1900.00cm * 900.00cm * 2100.00cm
Package Gross Weight
500.000kg

Product Description

 
Product Description

Ductless fume hoods make work safer in laboratories and help protect the environment. Up until the1960s, laboratories used vented hoods to exhaust polluted air directly into the atmosphere which damaged many environmental resources and put people that lived and worked near the laboratories in danger. Ductless fume hoods completely eliminate the discharge of pollutants into the air and help protect operators from harmful airborne toxins.

Ductless fume hoods are equipped with numerous technological advances to enhance safety and function. Low airflow alarms ensure the proper containment of fumes inside the hood, filter saturation alarms help maintain near to zero chemical emissions in recirculated air and backup safety filters protect against filter malfunction.

Product Parameters
 
                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
More About the Fume Hood

The biggest challenge with fume hood performance is that users usually cannot see the hazards-most are invisible and odorless. Therefore, there is no easy way to know if your fume hood is working properly and protecting you. Many think that face velocity, which is defined as the speed of the air entering the sash opening, is an indication of safety. The ANSI/AIHA Z9.5 Laboratory Ventilation states: "Face velocity had been used historically as the primary indicator of laboratory hood performance for several decades. However, studies involving large populations of laboratory fume hoods tested using a containment-based test like the ANSI/ASHRAE Standard 110, 'Method of Testing the Performance of Laboratory Fume Hoods,' reveal that face velocity alone is an inadequate indicator of hood performance." In fact, most hoods that fail containment testing have acceptable face velocity readings.

Fume hoods and accessories represent one of the largest expenditures that a laboratory manager faces. The cost of air filtration does not end at the initial purchase price of a fume hood. Construction of ductwork and placement of utilities may be a one-time expense, however the ongoing cost of power and the increased HVAC load on the facility can be significant.

Traditional "ducted" fume hoods are connected to existing facility ductwork and pull contaminated air through the hood and direct it outside the facility and into the atmosphere. Ducted fume hoods can be filtered or unfiltered depending on the design and application. Ductless fume hoods contain filters which clean contaminated air and recirculate it directly back into the laboratory. No additional ductwork is required to exhaust air to the outside. Ductless fume hoods provide the same filtration capabilities as ducted hoods, but are easier to install, have lower initial installation costs and can be highly efficient.
Detailed Photos
                 
Acid & Alkali Resistant Laboratory Fume Hood with Movable Sash
Acid & Alkali Resistant Laboratory Fume Hood with Movable Sash
 
Acid & Alkali Resistant Laboratory Fume Hood with Movable Sash
Acid & Alkali Resistant Laboratory Fume Hood with Movable Sash
 
Fume Hood Maintenance
 

Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.

• In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.

 Fume  hoods should  be certified, at  least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies  have shown that face velocity is not a good predictor of fume hood leakage.

• Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.

 Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from  exposure to vapors,  aerosols, toxic  materials,  odorous,  and  other  harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.
FAQ

6 Questions to Ask When Buying a Fume Hood:

-Which chemicals will you use within the hood?

-Is a ducted or ductless hood best suited to your needs and available space?

-Where will you place the fume hood in the lab? Consider workflows, access to external exhaust systems, and competing air patterns.

-What size fume hood will best suit your needs? Be sure to consider what (if any) equipment will be enclosed in the hood.

-Are any service fixtures or accessories such as airflow monitors, electrical outlets, water, or gas fixtures required?

-Are base cabinets for acid, solvent, or non-chemical storage required?

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier