• Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
  • Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
  • Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
  • Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
  • Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
  • Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof

Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof

Material: Stainless Steel
Type: Slit Type
Function: Exhaust, Velocity Control
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof pictures & photos
Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
US $4,500-8,500 / Set
Min. Order: 1 Set
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Sichuan, China
Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (10)
  • Overview
  • Product Description
  • Product Parameters
  • More About the Fume Hood
  • Detailed Photos
  • Fume Hood Maintenance
  • FAQ
Overview

Basic Info.

Model NO.
WJ-1500B
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
Grey
Customized
Customized
Condition
New
Product Name
Laboratory Fume Hood
Base
Steel
Work Surface
20+6 mm Ceramic
Interior Baffle
Ceramic
Liner Material
Ceramic Fiber
Sash
5mm Tempered Glass
Airflow
Ceramic Fiber
Storage Cabinet
Multi-Layer Solid Wood
Application
Environment/Institute/Biology Lab/Chemical Lab
Transport Package
Standard Export Wooden Case Packing
Specification
1500*1205*2400 MM
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Packaging & Delivery

Package Size
1900.00cm * 900.00cm * 2100.00cm
Package Gross Weight
500.000kg

Product Description

Product Description

A fume hood is a ventilated, enclosed workspace intended to capture, contain and exhaust harmful or dangerous chemical fumes, vapors and particulate matter generated by procedures conducted within the hood. No HEPA filtration of either the intake or exhaust air takes place. The air is exhausted outside the laboratory. This makes a fume hood most suitable for chemical use and other work where sterility is not a concern. Fume hoods should be utilized for hazardous drug or chemical preparation and use with waste anesthetic gases such as isoflurane.

A Laminar Flow Hood (LFH), is not a biological safety cabinet. These devices do not provide any protection to
 the worker. They are designed to provide a sterile environment to protect the product. Air potentially contaminated with infectious agents may be blown towards the worker. LFHs should only be used for work with non-infectious materials such as media preparation. They should never be used with potentially infectious materials, toxins, volatile chemicals, or materials that may cause hypersensitivity to the worker such as animal dander.


A Biological Safety Cabinet (BSC) is a valuable supplement to good sterile technique and a necessary containment device when working with potentially infectious materials. All BSCs use high efficiency particulate air (HEPA) filters to treat intake and exhaust air. These filtered cabinets are primarily designed to protect against exposure to particulates or aerosols. 70% of the air in most BSCs is recirculated back into the lab through its exhaust HEPA filter. This purifies the air of potentially infectious aerosols and animal dander or bedding but does not reduce exposure to chemicals or gases including waste anesthetic gases such as isoflurane.

    Product Parameters
      
    Model
    Parameters
    YT-1500A YT-1500B YT-1500C YT-1800A YT-1800B YT-1800C
    Size (mm) 1500(W)*865(D)*2400(H) 1800(W)*1205(D)*2400(H)
    Worktop Size (mm) 1260(W1)*795(D1)*1100(H1) 1560(W1)*795(D1)*1100(H1)
    Worktop 20+6mm Ceramic 20+6mm Ceramic 12.7mm Solid Physiochemical Board 20+6mm Ceramic 20+6mm Ceramic 12.7mm Solid Physiochemical Board
    Liner 5mm Ceramic Fibre 5mm Compact Laminate 5mm Compact Laminate 5mm Ceramic Fibre 5mm Compact Laminate 5mm Compact Laminate
    Diversion Structure Back Absorption
    Control System Touch-Tone Control Panel (LED Screen)
    Input Power  220V/32A
    Fan Power Less than 2.8 A 
    Socket Max. Load 5KW
    Faucet 1 Set
    Drainage Mode  Natural Fall
    Storage Double-Lock, Corrosion-Resistant, Damp-proof, Multi-layer Solid Wood with Mobile Wheel
    Application Indoor No-blast, 0-40 ºC
    Application Field Organic Chemical Experiment
    Face Velocity Control Manual Control
    Average Face Velocity 0.3-0.5 m/s  Exhaust: 720-1200m³/h 0.3-0.5 m/s  Exhaust:900- 1490m³/h
    Face Velocity Deviation Less than 10%
    Average Illumination Less than 500  Lux
    Noise Within 55 dB
    Exhaust Air No Residue
    Safety Test In Accord with International Standard
    Resistance Less than 70Pa
    Add Air Function Distinctive Structure (Need Exclusive Add Air System)
    Air Flow Control Valve Dia. 250mm Flange Type Anti-Corrosion Control Valve Dia. 315mm Flange Type Anti-Corrosion Control Valve
    More About the Fume Hood

    Factors that Affect the Performance of a Fume Hood

    The following are common situations that can arise in laboratories that may negatively affect fume hood performance:

    -Objects obstructing the return ducts and baffle areas.
    Objects placed in close proximity to return ducts and baffles tend to interfere with air being pulled from the back portion of the fume hood. Place large equipment on stands to allow air flow underneath, remove unnecessary chemicals and equipment.

    -Objects and equipment too close to the front of the fume hood.
    This has the potential to create unwanted air currents that may allow contaminants to leave the front area of the fume hood and cause unwanted exposures. All equipment and materials should be placed at least 6 inches from the face of the fume hood. TIP: Use a length of tape to mark out six inches.

    -Secondary currents created by portable fans and traffic in front of the hood.
    These currents draw contaminants out of the fume hood. Do not direct any other ventilation (portable vans, HVAC ductwork) towards a fume hood. Limit pedestrian traffic in front of the hood while in use.

    Detailed Photos
          
    Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
    Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
    Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
     
    Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
    Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
    Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
     
    Fume Hood Maintenance

    Hoods should be evaluated by the user before each use to ensure adequate face velocities and the absence of excessive turbulence.

    • In case of exhaust system failure while using a hood, shut off all services and accessories and lower the sash completely. Leave the area immediately.

     Fume  hoods should  be certified, at  least annually, to ensure they are operating safely. Typical tests include face velocity measurements, smoke tests and tracer gas containment. Tracer gas containment tests are especially crucial, as studies  have shown that face velocity is not a good predictor of fume hood leakage.

    • Laboratory fume hoods are one of the most important used and abused hazard control devices. We should understand that the combined use of safety glasses, protective gloves, laboratory smocks, good safety practices, and laboratory fume hoods are very important elements in protecting us from a potentially hazardous exposure.

     Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from  exposure to vapors,  aerosols, toxic  materials,  odorous,  and  other  harmful substances. A secondary purpose is to serve as a protective shield when working with potentially explosive or highly reactive materials. This is accomplished by lowering the hood sash.
    FAQ

    Why do fume hoods use so much energy?
    It's the air being sucked through the fume hood, not the fume hood itself that consumes so much energy. For health and safety reasons, labs use 100% outside air which must be heated or cooled for comfort before it is brought into the lab. In addition to the energy required to condition the air, a significant amount of additional electricity is required to run large fans to move the air through the building and through the fume hoods.

    How does shutting the sash save energy?
    Most fume hoods at Stanford are variable air volume (VAV), meaning that the fume hoods are designed to vary the air flow based on how wide open the sash height is. Sash position is connected to the building's ventilation system so that a building's fan speed and the volume of air moved is reduced when the sash is lowered.

    Is it safe to shut the sash?
    The sash is an important safety barrier between the fume hood interior and the laboratory, protecting the lab user. Sashes should be opened only to set up or modify an experiment. At all other times, shutting the sash is safest. When the sash is shut there is still some air flow through the hood to remove any fumes.

    How do I remind myself and my roommates to close the sash?
    You can post a sticker, like the one shown in the picture below, to remind yourself and your lab mates to close the sash when not in use. The sticker also educates new fume hood users tha a lower sash is safer, and that the sash should only be open when setting up and modifying experiments.

    What other fume hood practices can reduce my energy consumption?
    • Never use a fume hood just for storing chemicals - they belong in a safety cabinet, which doesn't require huge volumes of air.
    • If your fume hood has an occupancy switch, turn it off when not in use.
    • If your group is no longer using a specific fume hood, consider having it locked and de-commissioned so air no longer flows through it.

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now

    You Might Also Like

    From payment to delivery, we protect your trading.
    Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof pictures & photos
    Acid & Alkali Resistant Fireproof Heat Resistant Chemical Duct Laboratory Fume Hood Explosion Proof
    US $4,500-8,500 / Set
    Min. Order: 1 Set
    Diamond Member Since 2022

    Suppliers with verified business licenses

    Secured Trading Service
    Manufacturer/Factory
    Plant Area
    101~500 square meters
    Management System Certification
    ISO 9001