Product Highlights
- Ductless Air Filtration: Recirculates clean air without exterior ducting or makeup air requirements.
- Customized Product Options: Available in customized configurations including worktop, liner, and sash materials.
- Energy Cost Savings: Significant energy savings compared to ducted systems due to recirculation.
- No Permitting Issues: Eliminates the need for external venting permits and EPA air sampling.
- High Corrosion Resistance: Constructed with stainless steel and ceramic materials for acid/alkali resistance.
- Touch-Tone Control System: Features LED screen for precise face velocity and exhaust control.
- Portable and Adaptable: Mobile design with wheels allows easy layout changes and mobility.
- Safety Compliance: Meets international safety standards for chemical and gas containment.
Product Attributes
- Customization
- Available
- Material
- Stainless Steel
- Type
- Slit Type
- Model NO.
- WJ-DM1600
- Function
- Exhaust, Velocity Control
- Feature
- Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
- Hood Type
- Standard
- Color
- Grey
- Customized
- Customized
- Condition
- New
- Product Name
- Ductless Fume Hood
- Worktop
- 20+6 mm Ceramic
- Liner Material
- Ceramic Fiber Board
- Sash
- Tempered Glass
- Filter
- 370*395*50mm
- Input Power
- 110V-240V
- Face Velocity
- 0.4-0.6 M/S
- Application
- Environment/Institute/Biology Lab/Chemical Lab
- Transport Package
- Standard Export Wooden Case Packing
- Specification
- 1600*620*1245 MM
- Trademark
- Ample
- Origin
- Chengdu, China
- HS Code
- 8414809090
- Production Capacity
- 200 Set/Month
- Package Size
- 1900.00cm * 900.00cm * 2100.00cm
- Package Gross Weight
- 360.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of High Quality Custom Wholesale OEM Laboratory Fume Cupboard Chemical Fume Hood
Find Similar Products
Product Description
A ductless fume hood is a stand alone, compact workstation that provides a continuous flow of air that filters hazardous fume vapors out, recirculating clean air back into your working environment. Because the air is recirculated, no exterior ducting or makeup air is necessary. These air filtration systems are designed to keep harmful airborne contaminants away from the operator's respiratory zone while they work within the hood.
Also referred to as exhaust hoods, these containment systems are used for a variety of applications including chemical fume control, powder and dust removal, solvent vapor control, pharmaceutical powder filling, light grinding, acid gas fumes, anesthesia gas containment, epoxy fume control and other applications that produce hazardous particulates and fumes.
Ductless fume hoods offer several key advantages when weighing your options versus a ducted fume hood:
-No costly ducting or venting
-No permitting issues for venting outside of the building
-Adaptable (mobility and ease in change of layout)
-Environmentally friendly
-Significant energy cost saving
| Model Parameters |
YT-1500A | YT-1500B | YT-1500C | YT-1800A | YT-1800B | YT-1800C |
| Size (mm) | 1500(W)*865(D)*2400(H) | 1800(W)*1205(D)*2400(H) | ||||
| Worktop Size (mm) | 1260(W1)*795(D1)*1100(H1) | 1560(W1)*795(D1)*1100(H1) | ||||
| Worktop | 20+6mm Ceramic | 20+6mm Ceramic | 12.7mm Solid Physiochemical Board | 20+6mm Ceramic | 20+6mm Ceramic | 12.7mm Solid Physiochemical Board |
| Liner | 5mm Ceramic Fibre | 5mm Compact Laminate | 5mm Compact Laminate | 5mm Ceramic Fibre | 5mm Compact Laminate | 5mm Compact Laminate |
| Diversion Structure | Back Absorption | |||||
| Control System | Touch-Tone Control Panel (LED Screen) | |||||
| Input Power | 220V/32A | |||||
| Fan Power | Less than 2.8 A | |||||
| Socket Max. Load | 5KW | |||||
| Faucet | 1 Set | |||||
| Drainage Mode | Natural Fall | |||||
| Storage | Double-Lock, Corrosion-Resistant, Damp-proof, Multi-layer Solid Wood with Mobile Wheel | |||||
| Application | Indoor No-blast, 0-40 ºC | |||||
| Application Field | Organic Chemical Experiment | |||||
| Face Velocity Control | Manual Control | |||||
| Average Face Velocity | 0.3-0.5 m/s Exhaust: 720-1200m³/h | 0.3-0.5 m/s Exhaust:900- 1490m³/h | ||||
| Face Velocity Deviation | Less than 10% | |||||
| Average Illumination | Less than 500 Lux | |||||
| Noise | Within 55 dB | |||||
| Exhaust Air | No Residue | |||||
| Safety Test | In Accord with International Standard | |||||
| Resistance | Less than 70Pa | |||||
| Add Air Function | Distinctive Structure (Need Exclusive Add Air System) | |||||
| Air Flow Control Valve | Dia. 250mm Flange Type Anti-Corrosion Control Valve | Dia. 315mm Flange Type Anti-Corrosion Control Valve | ||||
A ductless fume hood may not be suitable for the application being practiced as there are certain features of a ducted hood that may suit your needs more:
Certain chemicals/gases carry a low molecular weight and are not efficiently captured through a carbon filter (ie. methane, butane, propane gas)
Loading: the amount of uses per time frame may require us to directly vent outside versus running through a particular filter "too much"
For example: If your application is using acetone gas and evaporating gallons per day, running it through a carbon filter in excess may saturate it past an effective point, rendering it to be useless or replaced at a significant rate.
Benefits of a Ductless Fume Hood
-Minimal installation costs-no external ducting or venting
-Portable
-Minimal maintenance
-Environmentally friendly
-Significant energy cost savings
-No permitting issues for venting outside (ie. EPA air sampling
What Is a Fume Hood?
A fume hood is a piece of laboratory equipment designed to minimize a person's exposure to hazardous chemicals. The fume hood draws away harmful vapors so lab employees can work with chemicals without the risk of accidental exposure. The air is extracted from the fume hood and filtered to remove dangerous vapors, and then either exhausted outside of the building or recirculated back into the lab.
How Does a Fume Hood Work?
The fume hood works by using a sash (a window that opens or closes to protect the user) to contain the vapor and keep it away from the user's face or to prevent it from drifting out into the rest of the laboratory. Blowers draw in air from the room, through a filter or number of filters within the fume hood and towards an exhaust area.
To safely work in a fume hood, keep all work at least six inches away from the plane of the sash. This will ensure fumes are pulled away from the user. Also, make sure the hood sash remains closed as much as possible and keep the hood slots and baffles free of any obstructions by containers or equipment. Never place your head inside the fume hood when working with chemicals.
The airflow will differ depending on the type of hood you use. For a constant air volume (CAV) hood, the fan has only one speed, providing a stable and continuous airflow. A variable air volume (VAV) hood allows users to adjust the velocity of the exhaust for added versatility, while reduced air volume (RAV) hoods offer lower airflow performance, making them ideal for working with less harmful compounds.
It's the air being sucked through the fume hood, not the fume hood itself that consumes so much energy. For health and safety reasons, labs use 100% outside air which must be heated or cooled for comfort before it is brought into the lab. In addition to the energy required to condition the air, a significant amount of additional electricity is required to run large fans to move the air through the building and through the fume hoods.
How does shutting the sash save energy?
Most fume hoods at Stanford are variable air volume (VAV), meaning that the fume hoods are designed to vary the air flow based on how wide open the sash height is. Sash position is connected to the building's ventilation system so that a building's fan speed and the volume of air moved is reduced when the sash is lowered.
Is it safe to shut the sash?
The sash is an important safety barrier between the fume hood interior and the laboratory, protecting the lab user. Sashes should be opened only to set up or modify an experiment. At all other times, shutting the sash is safest. When the sash is shut there is still some air flow through the hood to remove any fumes.
How do I remind myself and my roommates to close the sash?
You can post a sticker, like the one shown in the picture below, to remind yourself and your lab mates to close the sash when not in use. The sticker also educates new fume hood users tha a lower sash is safer, and that the sash should only be open when setting up and modifying experiments.

About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR238059". Items marked "" are certified.
Company Profile
Chengdu Ample Import and Export Co., Ltd. is a professional solution-oriented supplier aiming to be one of the leading Exporter and Manufacturer of Laboratory furniture such as lab fume hoods, lab storage cabinets, and benches, Office chairs, with well-equipped testing facilities and strong technical force.
Our products are extensively used in many industry fields with a wide range, good quality, reasonable prices, and advanced designs.
One of the Ample factories specializes in laboratory protective products to meet the requirements of different kinds of laboratory experiments. We also supply customers with China's Top-quality medical devices at the factory-direct price.
We both provide customized products and OEM service for our all products.
Our company tenet is Top in Quality, Best in Service.
Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs.
We sincerely welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
About Our Factory & Business Background
- Address
- No. 11, 11th Floor, Unit 2, Building 2, No. 1, Section 1, Huayang Huafu Avenue, Tianfu New District, Chengdu, Sichuan, China
- Terms of Payment
- LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, EXW, CIF
- Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2019-07-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What is a fume hood?
- A fume hood is laboratory equipment designed to minimize exposure to hazardous chemicals by drawing away harmful vapors and filtering them before exhausting or recirculating the air.
- How does a fume hood work?
- It uses a sash to contain vapors and blowers to draw air through filters. Work should be kept at least six inches from the sash plane, and the sash should remain closed as much as possible.
- Why do fume hoods use so much energy?
- Energy is consumed by the fans moving air and conditioning 100% outside air to comfort temperatures before it enters the lab.
- How does shutting the sash save energy?
- Variable air volume (VAV) hoods reduce fan speed and air volume when the sash is lowered, connecting to the building's ventilation system.
- Is it safe to shut the sash?
- Yes, shutting the sash is the safest practice when not actively setting up or modifying an experiment, as it maintains a safety barrier while allowing some airflow.
- How can I remind users to close the sash?
- Post a sticker near the hood to educate users that a lower sash is safer and should only be opened during experiment setup.
- What are the lead times for this product?
- Peak season lead time is one month, while off-season lead time is within 15 workdays.
- What payment terms are accepted?
- Accepted payment methods include LC, T/T, PayPal, Western Union, Small-amount payment, and Money Gram.
Send your message to this supplier
People who viewed this also viewed
-
US$4,400.00-5,080.00 / Piece
-
US$4,400.00-5,080.00 / Piece
-
US$4,500.00-6,500.00 / Set
-
US$4,500.00-6,500.00 / Set
-
US$1,500.00-4,000.00 / Set
Find Similar Products By Category
- Supplier Homepage
- Products
- Ductless Fume Hood
- High Quality Custom Wholesale OEM Laboratory Fume Cupboard Chemical Fume Hood
Related Categories
Hot Searches
- Furniture Equipment
- Supermarket Equipment Factories
- Store Equipment Factories
- Portable Bed Factories
- New Fume Hood
- Steel Fume Hood
- Lab Fume Hood
- Fume Hood For Laboratory
- Bench Fume Hood Laboratory
- Ductless Fume Hood Bulkbuy