Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab

Product Details
Customization: Available
Material: PP
Type: Bypass Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab
  • Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab
  • Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab
  • Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab
  • Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab
  • Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Common Applications
  • Detailed Photos
  • Application Cases
Overview

Basic Info.

Model NO.
WXL-1500A-850-1
Function
Exhaust, Velocity Control
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
White
Customized
Customized
Condition
New
Product Name
Ductless Fume Hood
Worktop
1426*712*791 mm
Input Power
220V/50-60Hz
Face Velocity
0.4-0.6
Application
Hospital, School, Laboratory, Inspection
Base Material
Polypropylene
Faucet
UPVC
Transport Package
Standard Export Wooden Case Packing
Specification
1500*850*1940 mm
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Packaging & Delivery

Package Size
1900.00cm * 900.00cm * 2100.00cm
Package Gross Weight
360.000kg

Product Description

Product Description


Probably the most important consideration is the type of chemicals that your laboratory uses. The majority of ductless fume cabinets are only suitable for process-specific or light-duty fumes. Before you decide if this unit is right for you, compile a list of all the chemicals and the quantities of each. From this, you should be able to determine if a ductless hood would work in your lab. If your laboratory use is likely to change over time, or you do not know what type of chemicals will be used in future, then this fume extraction system might not be the best choice for you. The safety and health of your employees or operators should be your top priority, so the type of chemicals you are using will be the main deciding factor on whether a ductless fume hood is right for you.

Also known as a recirculating fume enclosure or a filtered fume hood, a ductless unit is self-contained and works to remove toxic molecules, particles and vapour from the air. Having a chemical fume cabinet is likely to be the most essential piece of safety equipment your workplace can have. They clean the contaminated air to deliver clean air back into the environment. Compared with other types of chemical fume hoods, the ductless solutions can be more cost-efficient, easier to install and don't require ductwork around the building. Despite all these benefits, ductless fume hoods are not suitable for every situation. There are a few factors that you need to take into account before deciding if a this type of fume cupboard is suitable for your laboratory.

Product Parameters

 

                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Common Applications


Ductless fume hoods are used in various fields. Some of the most common applications are the following:

  • Life Sciences
  • Forensics, Fingerprinting and DNA
  • Educational Purposes
  • Clinics and Hospitals
  • Dental Laboratory
  • Cleanrooms
  • 3D Printing
  • Archaeology
  • Glass Manufacturing
  • Mycology
  • Soldering
  • Pharmaceutical
  • Art Restoration
  • Production of Glues, Paints, and Solvents
Detailed Photos
       
Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab
Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab
 
Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab
Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab

Application Cases

Choosing the right fume hood for your laboratory can be a challenge, and ductless fume hoods could be the solution you have been looking for. Whether you are working in an educational laboratory or an industrial location, having the right fume hood at your disposal is crucial. This piece of equipment is so important for the safety of your lab and your team, so choosing the right one is vital.

Another critical factor to consider is the cost of a recirculating fume hood. We have already mentioned that this system can often be more cost-effective than a ducted
 alternative. A ducted system needs to have an expensive infrastructure around it, such as ducting, mechanical systems, exhaust fans, roof elements and more. All of these things are an additional cost to consider. A filtered hood eliminates all of these extra costs, but that does not mean they are free to run. Ductless hoods will need regular filter replacements, which is an expenditure that needs to be taken into account.

Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab
Acid and Alkali Resistant Chemical Ductless Fume Hood for Lab

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier