Secured Trading Service

Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A

Chengdu Ample Import and Export Co., Ltd.
  • Audited Supplier
  • 5 yrs

Contact Supplier

Product Highlights

  • Customized Dimensions: Built to fit specific space requirements and unusual size needs.
  • Corrosion Resistance: Constructed with ceramic materials to withstand highly corrosive acids.
  • Heat Resistant: Designed for high-temperature environments with fireproof capabilities.
  • Vertical Sliding Window: Counterbalanced sash provides maximum working area and operator access.
  • Precise Velocity Control: Manual control system adjusts exhaust volume for stable airflow.
  • High Efficiency Purification: Spray sodium hydroxide solution removes hazardous vapors effectively.
  • LED Illumination: Adjustable white and UV-free yellow LED lamps with over 700 Lux intensity.
  • Low Noise Operation: Operates within 55 decibels for a quiet laboratory environment.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A

Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A pictures & photos
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A pictures & photos
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A pictures & photos
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A pictures & photos
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A pictures & photos
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A pictures & photos
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
  • Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
  • Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
    Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
  • Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
    Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
  • Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
    Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
  • Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
    Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
  • Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
    Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
  • Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
    Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A

Find Similar Products

Product Description

Product Description

Fume Hood Tips

Size.
 A basic starting point when shopping for and specifying a fume hood is size. What size is the working area required for your application? What size is the available space on the factory floor or the laboratory for a fume hood? Best Technology builds custom fume hoods, so even if your size requirements are unusual, we can build a fume hood to fit your space.


Materials. Some chemistries require specialized materials for containment. Highly corrosive acids at high concentrations, for example, often require a fume hood constructed from polypropylene rather than stainless steel for better corrosion resistance. For hydrofluoric acid, polycarbonate is the preferred material for the sash, to avoid etching of a glass window. Knowing the expected chemistry that will be put in the fume hood is crucial to ensuring years of reliable functioning.

Standards. Does your fume hood need to meet certain industry standards? Does your chemical process need to meet other specialized standards or requirements? Sometimes a "one-size-fits-all" fume hood just won't work. In those cases, look to the applications engineers at Best Technology for a customized fume hood.

Window orientation. Some fume hoods use a horizontal sliding window, which limits the access of the operator to the working area inside the fume hood. Look for a vertically sliding window (sash), so that users have more available working area in the interior of the fume hood. Best Technology offers fume hoods with counterbalanced, vertically sliding windows.

Product Parameters

 

                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Guidelines

 Keeping the sash as low as possible, and closed when not in operation, reduces energy costs. Since the fume hood exhausts conditioned air (heated or cooled, depending on local climate), reducing the amount of exhaust reduces the load on the facility's HVAC system.

Be aware that sash position can affect air velocity within the enclosure such that a closed sash may have enough increased airflow to disturb delicate parts or instruments. Some fine-tuning of the blower speed may be required to find the balance that works for you.

Detailed Photos

Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A

Application Cases

A properly operating and correctly used fume hood will protect workers by containing vapors, dusts, gases, and mists. The sash can also act as a shield to workers from splashes and minor explosions or fires that may occur inside the hood. A fume hood is not designed to protect the skin or hands of workers placed inside the fume hood during activities. Personal Protective equipment (eye protection, gloves and lab coat) must be used to protect the skin that is exposed to the open area of the fume hood.

Fume hoods are the primary engineering controls used to control inhalation exposures to hazardous substances in University research buildings. There are other types of local exhaust such as vented enclosures for large pieces of equipment or chemical storage, and snorkel and canopies for capturing contaminants near the point of release. Work is performed directly underneath the canopy or snorkel and is typically intended for machines such as gas chromatographs or mass spectrometers. This type of local exhaust does not guarantee 100% removal of gases.
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A
Heat Resistant Ceramic Fiber Duct Fume Cupboard Fireproof 380V/50A

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR238059". Items marked "verified" are certified.

Watch Video
Watch Video
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.
Chengdu Ample Import and Export Co., Ltd.

About Our Factory & Business Background

Address
No. 11, 11th Floor, Unit 2, Building 2, No. 1, Section 1, Huayang Huafu Avenue, Tianfu New District, Chengdu, Sichuan, China
Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main Products
Chemical Fume Hood, Laboratory Fume Hood, Duct Fume Hood, Laboratory Furniture, Laboratory Storage Cabinet, Laboratory Equipment, Hospital Bed, Medical Device, Oxygen Concentrator, Veterinary Medical Equipment

Our Industry Experience & Global Business Record

Export Year
2019-07-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

Can the fume hood be customized to fit specific space requirements?
Yes, Best Technology builds custom fume hoods to fit unusual size requirements and available factory or laboratory space.
What materials are used for corrosion resistance?
The hood uses 20+6mm thick butterfly ceramics for the panel and 5mm thick ceramic fiber board for internal lining to handle highly corrosive acids.
How is the air velocity controlled?
It features manual control through an electric air valve to adjust exhaust volume or by adjusting the height of the moving door.
What is the illumination standard for the hood?
It includes adjustable Standard white and UV-free yellow LED lamps with an intensity of not less than 700 Lux.
Is the fume hood suitable for explosion-proof environments?
It is designed for non-explosion indoor use, though it offers explosion-proof features for safety.
What is the power consumption of the unit?
Power consumption is less than 1.0kw/h or 1.2kw/h depending on the model, excluding fans and external instruments.
How is the purification system operated?
It uses a spray of sodium hydroxide solution with a flow rate of no less than 8 or 12 cubic meters per hour.
What is the maximum load capacity of the socket?
The maximum load of the socket is 12 KW, which is the total for 4 sockets.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now