Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory

Product Details
Customization: Available
Material: Stainless Steel
Type: Bypass Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory
  • Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory
  • Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory
  • Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory
  • Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory
  • Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Specialty Designs
  • Detailed Photos
  • FAQ
Overview

Basic Info.

Model NO.
WJ-1500B
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
Grey
Customized
Customized
Condition
New
Product Name
Fume Cupboard
Worktop
Ceramic
Liner Material
Ceramic Fiber Board
Input Power
380V/50A
Face Velocity
0.5
Application
School/University/Biology Lab/Chemical Lab
Transport Package
Standard Export Wooden Case Packing
Specification
1500W*1205D*2400H (MM)
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Packaging & Delivery

Package Size
1900.00cm * 900.00cm * 2100.00cm
Package Gross Weight
500.000kg

Product Description


 
Product Description

A fume hood is typically a large piece of equipment enclosing five sides of a work area, the bottom of which is most commonly located at a standing work height.

Two main types exist, ducted and recirculating (ductless). The principle is the same for both types: air is drawn in from the front (open) side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room. This is used to:

  • protect the user from inhaling toxic gases (fume hoods, biosafety cabinets, glove boxes)
  • protect the product or experiment (biosafety cabinets, glove boxes)
  • protect the environment (recirculating fume hoods, certain biosafety cabinets, and any other type when fitted with appropriate filters in the exhaust airstream)

Most fume hoods for industrial purposes are ducted. A large variety of ducted fume hoods exist. In most designs, conditioned (i.e. heated or cooled) air is drawn from the lab space into the fume hood and then dispersed via ducts into the outside atmosphere.

The fume hood is only one part of the lab ventilation system. Because recirculation of lab air to the rest of the facility is not permitted, air handling units serving the non-laboratory areas are kept segregated from the laboratory units. To improve indoor air quality, some laboratories also utilize single-pass air handling systems, wherein air that is heated or cooled is used only once prior to discharge. Many laboratories continue to use return air systems to the laboratory areas to minimize energy and running costs, while still providing adequate ventilation rates for acceptable working conditions. The fume hoods serve to evacuate hazardous levels of contaminant.

To reduce lab ventilation energy costs, variable air volume (VAV) systems are employed, which reduce the volume of the air exhausted as the fume hood sash is closed. This product is often enhanced by an automatic sash closing device, which will close the fume hood sash when the user leaves the fume hood face. The result is that the hoods are operating at the minimum exhaust volume whenever no one is actually working in front of them.

 
Product Parameters
 
                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Specialty Designs

Acid digestion

These units are typically constructed of polypropylene to resist the corrosive effects of acids at high concentrations. If hydrofluoric acid is being used in the hood, the hood's transparent sash should be constructed of polycarbonate which resists etching better than glass. Hood ductwork should be lined with polypropylene or coated with PTFE (Teflon).

Downflow

Downflow fume hoods, also called downflow work stations, are typically ductless fume hoods designed to protect the user and the environment from hazardous vapors generated on the work surface. A downward air flow is generated and hazardous vapors are collected through slits in the work surface.

Perchloric acid

These units feature a waterwash system (scrubber - see below) in the ductwork. Because dense perchloric acid fumes settle and form explosive crystals, it is vital that the ductwork be cleaned internally with a series of sprays.

Radioisotope

This fume hood is made with a coved stainless steel liner and coved integral stainless steel countertop that is reinforced to handle the weight of lead bricks or blocks.

Scrubber

This type of fume hood absorbs the fumes through a chamber filled with plastic shapes, which are doused with a scrubbing medium. The chemicals are washed into a sump, which is often filled with a neutralizing liquid. The fumes are then dispersed, or disposed of, in the conventional manner.

Waterwash

These fume hoods have an internal wash system that cleans the interior of the unit, to prevent a build-up of dangerous chemicals.

 
Detailed Photos
 
Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory


Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory

Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory
FAQ


How a Fume Hood Works

A fume hood is a ventilated enclosure in which gases, vapors and fumes are captured and removed from the work area. An exhaust fan situated on the top of the laboratory building pulls air and airborne contaminants through connected ductwork and exhausts them to the atmosphere.

Depending on its design, the sash may move vertically, horizontally or a combination of the two and provides some protection to the hood user by acting as a barrier between the worker and the experiment.

The slots and baffles within the hood direct the air and, in many hoods, can be adjusted to allow the most even flow. It is important to prevent the baffles from becoming blocked, by excessive material storage or equipment, since this significantly affects the exhaust path within the hood and as a result, the efficiency of hood capture. 

The beveled frame around the hood face, called the airfoil, allows for even air flow into the hood by eliminating sharp curves to reduce turbulence.

Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory

Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier