Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant

Product Details
Customization: Available
Material: Stainless Steel
Type: Slit Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
  • Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
  • Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
  • Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
  • Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
  • Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • More About the Fume Hood
  • Detailed Photos
  • Application Cases
Overview

Basic Info.

Model NO.
WJ-1500A
Function
Exhaust, Velocity Control
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
White
Customized
Customized
Condition
New
Product Name
Chemical Fume Hood
Base
Steel
Work Surface
Ceramic
Airflow
Ceramic Fiber
Interior Baffle
Ceramic
Sash
Tempered Glass
Liner
Ceramic Fiber
Cabinet
Multi-Layer Solid Wood
Input Power
380V/50A
Face Velocity
0.6-0.8 M/S
Application
Office Building, Hospital, School, Laboratory
Illumination
Less Than 700 Lux
Transport Package
Standard Export Wooden Case Packing
Specification
1500(W)*1205(D)*2400(H)
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Packaging & Delivery

Package Size
1900.00cm * 900.00cm * 2100.00cm
Package Gross Weight
500.000kg

Product Description

Product Description

The fume hood is an important safety staple in chemistry classrooms and research labs. Getting the most out of a fume hood begins with selecting the right one for your application. That means knowing precisely what type of work will be performed in the fume hood and making the choice between constant air volume and variable air volume, choosing between a ducted and a ductless fume hood, and selecting the appropriate material of construction.

Type of Fume Hoood
-General Purpose Bench Top
The most common type of fume hood utilized in most types of labs. The liner
selected is generally fiberglass reinforced polyester (FRP) which has a broad application.

-General Purpose Floor Mount
Floor mounted hoods are used where the dimensions of the apparatus exceed what can be accommodated in a bench mounted fume hood or where the weight involved precludes placing the apparatus on a bench top.

High Performance Hoods-
High performance hoods allow greatly reduced face velocities at full working height, resulting in a 40-50% reduction in energy use as compared to a general purpose hood. These are generally restricted to common bench top general
purpose applications, suitable for VAV or CAV use.

Student workstations
Student workstations are generally deployed in undergraduate teaching lab
settings and are used by students while under supervision by instructor. Accordingly, materials of construction are adjusted to suit less demanding chemical resistance needs. Glass side and back windows are often provided. Often these hoods are placed on an island and are manufactured in a back-toback configuration with two working chambers.

Acid Digestion Hoods
- For operations involving heating and evaporation of acids, special materials are used in the construction of the hood interior. The principle changes include a PVC or polypropylene liner, polytetrafluoroethylene (PTFE) coated sash frame, lower airfoil and exhaust connection. In addition, if the hood will be used with hydroflouric acid, then the sash glass and light lens is changed from glass to polycarbonate.

Perchloric Acid Hoods
For operations involving heating and evaporation of perchloric acid, special
fume hoods are produced. These hoods are always bench top models with the addition of a wash-down system and drain trough to remove hazardous
perchlorate residues from the hood interior. Perchloric acid hoods are always connected to a dedicated exhaust system which is also equipped with a water
wash system. Perchloric acid hoods can be equipped with a stainless steel liner if they will be used with perchloric acid only or a PVC liner if they will be used with other acids as well.

Radioisotope Hoods
Radioisotope hoods are designed for use with radioactive materials and have a smooth coved stainless steel liner with an integral dished work surface. The work surface is reinforced to support the weight of heavy shielding which may need to be utilized by the user.

Product Parameters
 
Model
Parameters
YT-1500A YT-1500B YT-1500C YT-1800A YT-1800B YT-1800C
Size (mm) 1500(W)*865(D)*2400(H) 1800(W)*1205(D)*2400(H)
Worktop Size (mm) 1260(W1)*795(D1)*1100(H1) 1560(W1)*795(D1)*1100(H1)
Worktop 20+6mm Ceramic 20+6mm Ceramic 12.7mm Solid Physiochemical Board 20+6mm Ceramic 20+6mm Ceramic 12.7mm Solid Physiochemical Board
Liner 5mm Ceramic Fibre 5mm Compact Laminate 5mm Compact Laminate 5mm Ceramic Fibre 5mm Compact Laminate 5mm Compact Laminate
Diversion Structure Back Absorption
Control System Touch-Tone Control Panel (LED Screen)
Input Power  220V/32A
Fan Power Less than 2.8 A 
Socket Max. Load 5KW
Faucet 1 Set
Drainage Mode  Natural Fall
Storage Double-Lock, Corrosion-Resistant, Damp-proof, Multi-layer Solid Wood with Mobile Wheel
Application Indoor No-blast, 0-40 ºC
Application Field Organic Chemical Experiment
Face Velocity Control Manual Control
Average Face Velocity 0.3-0.5 m/s  Exhaust: 720-1200m³/h 0.3-0.5 m/s  Exhaust:900- 1490m³/h
Face Velocity Deviation Less than 10%
Average Illumination Less than 500  Lux
Noise Within 55 dB
Exhaust Air No Residue
Safety Test In Accord with International Standard
Resistance Less than 70Pa
Add Air Function Distinctive Structure (Need Exclusive Add Air System)
Air Flow Control Valve Dia. 250mm Flange Type Anti-Corrosion Control Valve Dia. 315mm Flange Type Anti-Corrosion Control Valve
More About the Fume Hood

Fume hoods get rid of vapors from any reactions or reagents lab workers may be using. But if you don't use the hood properly, you won't get the full safety benefits of this important piece of equipment and you could be exposed to the harmful fumes you're dealing with. These five points are good to keep in mind when working with a fume hood:

-To improve how well fumes are taken up and away, put your reactions or equipment as far back in the fume hood as you possibly can.
 
-Turn the unit's light on by using the switch near the electrical outlets on the outside panel.
 
-The safety shield or glass sash of the hood automatically drops to the right height for proper operation. Don't lift the sash above this height unless it's to put materials in or take them out of the hood. You should also keep the shield between the inside of the hood and your body. Lower the sash only if the height of the automatic stop is too high to protect your body and face. This may be common sense, but you should never climb inside the fume hood or stick your head inside it.
 
-If a splash occurs, wipe the glass of the fume hood clean and be sure to clean up any spills right away.
 
-Lower the safety shield to the height shown by the sticker on the side once you're done working with the fume hood.

Detailed Photos
            
Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
 
Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
 
Application Cases

Probably the most important consideration is the type of chemicals that your laboratory uses. The majority of ductless fume cabinets are only suitable for process-specific or light-duty fumes. Before you decide if this unit is right for you, compile a list of all the chemicals and the quantities of each. From this, you should be able to determine if a ductless hood would work in your lab. If your laboratory use is likely to change over time, or you do not know what type of chemicals will be used in future, then this fume extraction system might not be the best choice for you. The safety and health of your employees or operators should be your top priority, so the type of chemicals you are using will be the main deciding factor on whether a ductless fume hood is right for you.

Another critical factor to consider is the cost of a recirculating fume hood. We have already mentioned that this system can often be more cost-effective than a ducted alternative. A ducted system needs to have an expensive infrastructure around it, such as ducting, mechanical systems, exhaust fans, roof elements and more. All of these things are an additional cost to consider. A filtered hood eliminates all of these extra costs, but that does not mean they are free to run. Ductless hoods will need regular filter replacements, which is an expenditure that needs to be taken into account

Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant
Acid & Alkali Resistant Explosion Proof Ventilation Duct Laboratory Chemical Fume Cupboard with Heat Resistant

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier