Laboratory Polypropylene Fume Hood Customized for Chemical Experiment

Product Details
Customization: Available
Material: PP
Type: Bypass Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Laboratory Polypropylene Fume Hood Customized for Chemical Experiment
  • Laboratory Polypropylene Fume Hood Customized for Chemical Experiment
  • Laboratory Polypropylene Fume Hood Customized for Chemical Experiment
  • Laboratory Polypropylene Fume Hood Customized for Chemical Experiment
  • Laboratory Polypropylene Fume Hood Customized for Chemical Experiment
  • Laboratory Polypropylene Fume Hood Customized for Chemical Experiment
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Our Advantages
  • Detailed Photos
  • Application Cases
Overview

Basic Info.

Model NO.
WXL-1200A-850-2
Function
Exhaust, Velocity Control
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
Yellow
Customized
Customized
Condition
New
Product Name
PP Fume Cupboard
Worktop
1126*712*791 mm
Input Power
220V/50-60Hz
Face Velocity
0.4-0.6
Application
Experiment, Hospital, School, Laboratory
Cabinet
Polypropylene
Illumination
Less Than 500 Lux
Transport Package
Standard Export Wooden Case Packing
Specification
1200*850*1940 mm
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Packaging & Delivery

Package Size
1900.00cm * 900.00cm * 2100.00cm
Package Gross Weight
360.000kg

Product Description

Product Description

Used appropriately, a fume hood can be a very effective device for containment of hazardous materials, as well as providing some protection from splashes and minor over pressurizations. Even when used as designed, the average fume hood does have several limitations.

  • Projectiles: A fume hood is not designed to contain high velocity releases of particulate contaminants unless the sash is fully closed.
  • Pressurized systems: Gases or vapors escaping from pressurized systems may move at sufficient velocity to overcome the capture velocity and escape from the fume hood.
  • Explosions: The hood is not capable of containing explosions, even when the sash is fully closed. If an explosion hazard exists, the user should provide anchored barriers, shields or enclosures of sufficient strength to deflect or contain it. Such barriers can significantly affect the airflow in the hood.
  • Perchloric Acid: A conventional fume hood must not be used for perchloric acid. Perchloric acid vapors can settle on ductwork, resulting in the deposition of perchlorate crystals. Shock-sensitive perchlorates can accumulate on surfaces and have been known to detonate on contact, causing serious injury to researchers and maintenance personnel. Specialized perchloric acid hoods, made of stainless steel and equipped with a wash-down system must be used for such work.
Product Parameters
                Model Specification   WJ-1500A WJ-1500B WJ-1800A WJ-1800B
External dimensions of equipment(mm) 1500(W)*1205 (D) *2400 (H) 1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm) 1260(W1)*780(D1) *1100 (H1) 1560(W1)*780(D1) *1100 (H1)
Panel material 20+6mm thick butterfly ceramics
Material of internal lining board 5mm thick ceramic fiber board
Diversion structure Lower air return
Control system Button control panel (LCD panel)
PH value control The medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input power Three-phase five-wire 380V/50A
Current for air fan Not over 2.8A(380V or 220V can be directly connected)
Maximum load of socket 12 KW(total of 4 sockets)
Water tap 1 set (remote control valve + water nozzle) No 1 set (remote control valve + water nozzle) No
Water discharge way Magnetic chemical pump strong discharge
Using environment For non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fields Inorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of Purification Spray sodium hydroxide solution, no less than 8 cubic meters/hour Spray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed control Manual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed 0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm) 0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface air Not higher than 10%
The average intensity of illumination Not less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
Noise Within 55 decibels
Flow display White smoke can pass through the exhaust outlet, no overflow.
Safety inspection No spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinet Less than 160 pa
Power consumption Less than 1.0kw/h (excluding power consumption of fans and external instruments) Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumption Less than 3.2L/ h Less than 4.0L/ h
Performance of wind compensation With a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve 315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Our Advantages
  • Connections to the Exhaust System: Occasionally, a researcher may need local exhaust ventilation other than that provided by an existing fume hood. A new device may not be connected to an existing fume hood without the explicit approval of the department's facilities manager or Special Facilities supervisor. Adding devices to even the simplest exhaust system without adequate evaluation and adjustment will usually result in decreased performance of the existing hood and/or inadequate performance of the additional device.
  • Microorganisms: Work involving harmful microorganisms should be done in a biosafety cabinet, rather than a chemical fume hood. See the Biosafety Manual for more information.
  • Highly Hazardous Substances: A well designed fume hood will contain 99.999 - 99.9999% of the contaminants released within it when used properly. When working with highly dangerous substances needing more containment than a fume hood offers, consider using a glove box.
  • Pollution Control: An unfiltered fume hood is not a pollution control device. All contaminants that are removed by the ventilating system are released directly into the atmosphere. Apparatus used in hoods should be fitted with condensers, traps or scrubbers to contain and collect waste solvents or toxic vapors or dusts as appropriate.
Detailed Photos

Laboratory Polypropylene Fume Hood Customized for Chemical Experiment
Laboratory Polypropylene Fume Hood Customized for Chemical Experiment
Laboratory Polypropylene Fume Hood Customized for Chemical Experiment
Laboratory Polypropylene Fume Hood Customized for Chemical Experiment

Application Cases

When the exhaust is running, it sucks in volumes of air through the open side (never run the exhaust with the hood completely closed) and vents it through the duct. The duct may throw the fumes right outside the room in the air, or may run it through a filtration system, depending upon the severity of the experiment.

Some advanced laboratory fume hoods have microcontrollers inside them, which you can use to control the exhaust. You may set various suction levels for given setups and later use these quick setups for particular experiments. You can also control the fan/pump power during the experiment too, and the lights as well.
 
Inside the fume hood, there are facilities to let you work. For example, there is almost always some good lighting system in the cabinet. There should be LPG and water connections in the hood, and a drain too in case of spills. 

The air suction system is generally placed on top of the box or on the backside (the side towards the wall). This system is generally made up of a strong exhaust fan or air pump and accompanying air duct. The strength of the pump lies in the airflow strength starting from 4 to 8 meters per second to more. 

Laboratory Polypropylene Fume Hood Customized for Chemical Experiment