Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant

Product Details
Customization: Available
Material: Stainless Steel
Type: Slit Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
  • Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
  • Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
  • Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
  • Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
  • Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • More About the Fume Hood
  • Detailed Photos
  • Application Cases
  • FAQ
Overview

Basic Info.

Model NO.
WJ-1500B
Function
Exhaust, Velocity Control
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
Grey
Customized
Customized
Condition
New
Product Name
Fume Cupboard
Base
Steel
Work Surface
Ceramic
Airflow
Ceramic Fiber
Interior Baffle
Ceramic
Sash
Tempered Glass
Liner
Ceramic Fiber
Cabinet
Multi-Layer Solid Wood
Input Power
380V/50A
Face Velocity
0.6-0.8 M/S
Application
Office Building, Hospital, School, Laboratory
Illumination
Less Than 700 Lux
Transport Package
Standard Export Wooden Case Packing
Specification
1500(W)*1205(D)*2400(H)
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Packaging & Delivery

Package Size
1900.00cm * 900.00cm * 2100.00cm
Package Gross Weight
500.000kg

Product Description

Product Description

The fume hood is an important safety staple in chemistry classrooms and research labs. Getting the most out of a fume hood begins with selecting the right one for your application. That means knowing precisely what type of work will be performed in the fume hood and making the choice between constant air volume and variable air volume, choosing between a ducted and a ductless fume hood, and selecting the appropriate material of construction.

Type of Fume Hoood
-General Purpose Bench Top
The most common type of fume hood utilized in most types of labs. The liner
selected is generally fiberglass reinforced polyester (FRP) which has a broad application.

-General Purpose Floor Mount
Floor mounted hoods are used where the dimensions of the apparatus exceed what can be accommodated in a bench mounted fume hood or where the weight involved precludes placing the apparatus on a bench top.

High Performance Hoods-
High performance hoods allow greatly reduced face velocities at full working height, resulting in a 40-50% reduction in energy use as compared to a general purpose hood. These are generally restricted to common bench top general
purpose applications, suitable for VAV or CAV use.

Student workstations
Student workstations are generally deployed in undergraduate teaching lab
settings and are used by students while under supervision by instructor. Accordingly, materials of construction are adjusted to suit less demanding chemical resistance needs. Glass side and back windows are often provided. Often these hoods are placed on an island and are manufactured in a back-toback configuration with two working chambers.

Acid Digestion Hoods
- For operations involving heating and evaporation of acids, special materials are used in the construction of the hood interior. The principle changes include a PVC or polypropylene liner, polytetrafluoroethylene (PTFE) coated sash frame, lower airfoil and exhaust connection. In addition, if the hood will be used with hydroflouric acid, then the sash glass and light lens is changed from glass to polycarbonate.

Perchloric Acid Hoods
For operations involving heating and evaporation of perchloric acid, special
fume hoods are produced. These hoods are always bench top models with the addition of a wash-down system and drain trough to remove hazardous
perchlorate residues from the hood interior. Perchloric acid hoods are always connected to a dedicated exhaust system which is also equipped with a water
wash system. Perchloric acid hoods can be equipped with a stainless steel liner if they will be used with perchloric acid only or a PVC liner if they will be used with other acids as well.

Radioisotope Hoods
Radioisotope hoods are designed for use with radioactive materials and have a smooth coved stainless steel liner with an integral dished work surface. The work surface is reinforced to support the weight of heavy shielding which may need to be utilized by the user.

Product Parameters
 
Model
Parameters
YT-1500A YT-1500B YT-1500C YT-1800A YT-1800B YT-1800C
Size (mm) 1500(W)*865(D)*2400(H) 1800(W)*1205(D)*2400(H)
Worktop Size (mm) 1260(W1)*795(D1)*1100(H1) 1560(W1)*795(D1)*1100(H1)
Worktop 20+6mm Ceramic 20+6mm Ceramic 12.7mm Solid Physiochemical Board 20+6mm Ceramic 20+6mm Ceramic 12.7mm Solid Physiochemical Board
Liner 5mm Ceramic Fibre 5mm Compact Laminate 5mm Compact Laminate 5mm Ceramic Fibre 5mm Compact Laminate 5mm Compact Laminate
Diversion Structure Back Absorption
Control System Touch-Tone Control Panel (LED Screen)
Input Power  220V/32A
Fan Power Less than 2.8 A 
Socket Max. Load 5KW
Faucet 1 Set
Drainage Mode  Natural Fall
Storage Double-Lock, Corrosion-Resistant, Damp-proof, Multi-layer Solid Wood with Mobile Wheel
Application Indoor No-blast, 0-40 ºC
Application Field Organic Chemical Experiment
Face Velocity Control Manual Control
Average Face Velocity 0.3-0.5 m/s  Exhaust: 720-1200m³/h 0.3-0.5 m/s  Exhaust:900- 1490m³/h
Face Velocity Deviation Less than 10%
Average Illumination Less than 500  Lux
Noise Within 55 dB
Exhaust Air No Residue
Safety Test In Accord with International Standard
Resistance Less than 70Pa
Add Air Function Distinctive Structure (Need Exclusive Add Air System)
Air Flow Control Valve Dia. 250mm Flange Type Anti-Corrosion Control Valve Dia. 315mm Flange Type Anti-Corrosion Control Valve
More About the Fume Hood

Adequate planning and preparation are important when using a fume Hood. Knowing the standard operating procedure is also needed in order to maintain the equipments throughout.

Ensure that the exhaust is in good working condition before begining experiment. The baffles should be examined to check for obstructions. Airflow monitor should be checked to see if it is at the correct level,in a hood that has it.

Limit chemical exposure by keeping your face outside the plane.

Gears that will protect you where there is spills or fire is required. Such protective gears are gloves, splash googles and lab coat.

When the hood is not in use, keep it closed.

The sash should be closed to save energy.

When there is a suspicion of malfunction, or when the alarm for airflow goes off, terminate operations.

Don't suddenly remove it place items in the hood. This causes air disturbance, and the effectiveness of the equipment is reduced.

Instructions from the fume manufacturer should've read carefully. This prevents making mistakes

Detailed Photos
    
Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
 
Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
 
Application Cases

Probably the most important consideration is the type of chemicals that your laboratory uses. The majority of ductless fume cabinets are only suitable for process-specific or light-duty fumes. Before you decide if this unit is right for you, compile a list of all the chemicals and the quantities of each. From this, you should be able to determine if a ductless hood would work in your lab. If your laboratory use is likely to change over time, or you do not know what type of chemicals will be used in future, then this fume extraction system might not be the best choice for you. The safety and health of your employees or operators should be your top priority, so the type of chemicals you are using will be the main deciding factor on whether a ductless fume hood is right for you.

Another critical factor to consider is the cost of a recirculating fume hood. We have already mentioned that this system can often be more cost-effective than a ducted alternative. A ducted system needs to have an expensive infrastructure around it, such as ducting, mechanical systems, exhaust fans, roof elements and more. All of these things are an additional cost to consider. A filtered hood eliminates all of these extra costs, but that does not mean they are free to run. Ductless hoods will need regular filter replacements, which is an expenditure that needs to be taken into account

Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant
Explosion Proof Acid & Alkali Resistant Fireproof Duct Ventilation Laboratory Chemical Fume Cupboard with Heat Resistant

FAQ

Why do fume hoods use so much energy?
It's the air being sucked through the fume hood, not the fume hood itself that consumes so much energy. For health and safety reasons, labs use 100% outside air which must be heated or cooled for comfort before it is brought into the lab. In addition to the energy required to condition the air, a significant amount of additional electricity is required to run large fans to move the air through the building and through the fume hoods.

How does shutting the sash save energy?
Most fume hoods at Stanford are variable air volume (VAV), meaning that the fume hoods are designed to vary the air flow based on how wide open the sash height is. Sash position is connected to the building's ventilation system so that a building's fan speed and the volume of air moved is reduced when the sash is lowered.

Is it safe to shut the sash?
The sash is an important safety barrier between the fume hood interior and the laboratory, protecting the lab user. Sashes should be opened only to set up or modify an experiment. At all other times, shutting the sash is safest. When the sash is shut there is still some air flow through the hood to remove any fumes.

How do I remind myself and my roommates to close the sash?
You can post a sticker, like the one shown in the picture below, to remind yourself and your lab mates to close the sash when not in use. The sticker also educates new fume hood users tha a lower sash is safer, and that the sash should only be open when setting up and modifying experiments.

What other fume hood practices can reduce my energy consumption?
• Never use a fume hood just for storing chemicals - they belong in a safety cabinet, which doesn't require huge volumes of air.
• If your fume hood has an occupancy switch, turn it off when not in use.
• If your group is no longer using a specific fume hood, consider having it locked and de-commissioned so air no longer flows through it.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier