China Lab Ventilation System PP Fume Hood with Factory Price

US$9,500.00
1-9 Sets
US$8,500.00
10-49 Sets
US$6,500.00
50+ Sets
Port:
Guangzhou, China
Production Capacity:
200 Set/Month
Payment Terms:
L/C, T/T, D/P, Western Union, Paypal, Money Gram

Last Login Date:

Jun 28, 2025

Business Type:

Manufacturer/Factory

Main Products:

Chemical Fume Hood, Laboratory Fume Hood, Duct Fume Hood, Laboratory Furniture, Laboratory Storage Cabinet, Laboratory Equipment, Hospital Bed, Medical Device, Oxygen Concentrator, Veterinary Medical Equipment

Find Similar Products

Product Description

Company Info

Basic Info.

Model NO.
YC-1500A/YC-1800A
Type
Bypass Type
Function
Exhaust, Velocity Control
Feature
Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type
Standard
Color
Grey
Customized
Condition
New
Product Name
Fume Cupboard
Worktop
Ceramic
Liner Material
Ceramic Fiber Board
Input Power
380V/50A
Face Velocity
0.4-0.6
Application
Office Building, Hospital, School, Laboratory
Cabinet
PP
OEM
Yes
Trademark
Ample
Transport Package
Standard Export Wooden Case Packing
Specification
1500/1800W*1205D*2400H (MM)
Origin
Chengdu, China
HS Code
8414809090

Product Description

Product Description

fume hood, technically a laboratory chemical hood, is a type of local exhaust ventilation system (engineering control). A typical fume hood is cabinet with a moveable front sash (window) made out of safety glass. Air is drawn into the hood under and through the opened sash and is exhausted through openings in the rear and top of the cabinet to a remote point such as an exhaust stack on the roof of the building.

properly used and properly functioning fume hood exhausts hazardous gases, dustsmists, and vapors from a confined location and helps protect workers from inhalation exposure.

biological safety cabinet is similar to a fume hood in outward appearance but is designed for work with pathogens (infectious microorganisms) or materials contaminated with pathogens requiring a specific biosafety level.

Biosafety cabinets (BSC's) are designed to protect the user, the environment, and the material whereas fume hoods are designed to protect the user and others in that workspace. For example, a fume hood typically exhausts a toxic chemical to a roof stack where it is diluted to such a low concentration that it is unlikely to harm someone. In contrast, it would be a very bad idea to release a pathogen such as Ebola or virus to the environment, even if diluted, so biosafety cabinets are equipped with HEPA filters to remove the biological material. Biological safety cabinets may not be safe for use with toxic chemicals unless they exhaust the filtered air outside the lab/work space. There has been at least one report of an explosion caused by the use of flammable chemicals in a BSC.

Product Parameters
                Model Specification  WJ-1500AWJ-1500BWJ-1800AWJ-1800B
External dimensions of equipment(mm)1500(W)*1205 (D) *2400 (H)1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm)1260(W1)*780(D1) *1100 (H1)1560(W1)*780(D1) *1100 (H1)
Panel material20+6mm thick butterfly ceramics
Material of internal lining board5mm thick ceramic fiber board
Diversion structureLower air return
Control systemButton control panel (LCD panel)
PH value controlThe medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input powerThree-phase five-wire 380V/50A
Current for air fanNot over 2.8A(380V or 220V can be directly connected)
Maximum load of socket12 KW(total of 4 sockets)
Water tap1 set (remote control valve water nozzle)No1 set (remote control valve + water nozzle)No
Water discharge wayMagnetic chemical pump strong discharge
Using environmentFor non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fieldsInorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of PurificationSpray sodium hydroxide solution, no less than 8 cubic meters/hourSpray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed controlManual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm)0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface airNot higher than 10%
The average intensity of illuminationNot less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
NoiseWithin 55 decibels
Flow displayWhite smoke can pass through the exhaust outlet, no overflow.
Safety inspectionNo spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinetLess than 160 pa
Power consumptionLess than 1.0kw/h (excluding power consumption of fans and external instruments)Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumptionLess than 3.2L/ hLess than 4.0L/ h
Performance of wind compensationWith a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Guidelines

1. Check to be sure the hood has been inspected within the last 12 months.
2. Read the Safety Data Sheets for materials being used in a hood. Note the physical, chemical, and toxicological properties of materials being used before hand.
3. Turn on the light for proper illumination.
4. Keep the hood clear of clutter and unused materials. Do not use a hood for long term storage. Storage reduces air flow and compromises hood capture efficiency.
5. All work should be done at least six inches from the front of the hood.
6. When large equipment is used, place on blocks to allow for a two inch air flow gap under the equipment.
7. Always lower the sash when not working in the hood.
8. Never place your head in the hood while an experiment is on going.
9. Avoid quick movements while working or passing in front of the hood. Rapid movements may cause turbulence or a backwash resulting in hazardous vapor escape.
10. Campus Facilities Maintenance can adjust the baffle according to the nature of the work:
11. Fume hoods are not to be used for disposal of unwanted material. The cap of the unwanted materials bottle must seal the container.
12. Hoods designated for radioactive material use need to be approved by Radiation Safety before use.
13. Use of perchloric acid must be in a properly operating Perchloric Acid Hood with water wash capabilities.

Detailed Photos

Application Cases

A fume hood is a ventilated enclosure in which gases, vapors and fumes are captured and removed from the work area. An exhaust fan situated on the top of the laboratory building pulls air and airborne contaminants through connected ductwork and exhausts them to the atmosphere.

Depending on its design, the sash may move vertically, horizontally or a combination of the two and provides some protection to the hood user by acting as a barrier between the worker and the experiment.

Send your message to this supplier
Miss Lily Liu

Post a Sourcing Request Now

People who liked this also liked
Get Quick Quotes